Apikal Periodontitisin Yapay Zeka ile Tespitinde Referans Standartlar: Raporlanan Doğruluk Ölçütlerinin Anlatısal Bir Derlemesi

Reference Standards in Artificial Intelligence Detection of Apical Periodontitis: A Narrative Review of What Reported Accuracy Measures

Omar Rifat Alkhattab, Abdullah Bokhary

Kısa özet

Apikal periodontitisin yapay zeka (YZ) ile tespitinde raporlanan doğruluk, genellikle hastalığın tespitine göre yorumlanır, ancak bu genellikle doğru değildir; periapikal radyografi, histopatolojiye kıyasla lezyonların yalnızca %16-27'sini (paralaks ile %38) tespit ederken, YZ modelleri %61.0 duyarlılık ve %41.6 negatif prediktif değer raporlamaktadır.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Apikal periodontitis için raporlanan YZ doğruluğu sıklıkla aynı görüntünün insan okumalarını referans alır, gerçek hastalık varlığını değil.
  • Periapikal radyografi, histopatolojiye kıyasla teyit edilmiş lezyonların yalnızca %16-38'ini tespit eder.
  • YZ modelleri, bu daha az katı referanslara dayanarak %61.0 kümülatif dijital duyarlılık ve %41.6 negatif prediktif değer elde eder.
  • Tespit doğruluğu, lezyon boyutundan etkilenir; kesici dişlerde 1 mm'nin altında ve azı dişlerinde 3 mm'nin altında kalan küçük lezyonlar görünmezdir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

The accuracy reported for detecting apical periodontitis using artificial intelligence (AI) is generally interpreted as accuracy against the disease; however, this is usually not the case. Compared with histopathology, single-view periapical radiography detects 16 to 27% of confirmed lesions and 38% with parallax, with a pooled digital sensitivity of 61.0% and a negative predictive value of 41.6%. Two blinded specialists reading 1717 radiographs disagreed on 22% of teeth. Detection depended on lesion size and site: simulated cancellous-bone lesions were invisible below 1 mm in incisors and 3 mm in molars. Of the 44 primary studies identified, 34 (77%) used a label that was a reading of the index image or was unascertainable; eight (18%) used an independent reference—six (14%) suited to contemporaneous detection and two to later treatment outcomes. No cone-beam computed tomography (CBCT) input study had a reference independent of its volume. One commercial platform reported 92.3% sensitivity against same-image consensus and 47.9% against blinded CBCT. The reported accuracy is thus in agreement with a noisy rater; recognising this changes what meta-analyses pool. A model that reproduces human labels would have a lower sensitivity against disease than reported; for real-world models, the direction depends on error dependence that the study design cannot identify.

Yazarların özeti; kaynağından alınmıştır. Diagnostics, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Ağız Cerrahisi

Oral SurgeryDentistry