Kısa özet

2025 yılında yapılan ve Kore'deki tüm 47 üçüncü basamak hastaneyi kapsayan bir anket, ortalama MR güvenliği olgunluk puanının 100 üzerinden 63.08 olduğunu ortaya koydu; ferromanyetik tespit sistemleri ve MRSO atamaları gibi kritik alanlarda uyumluluk yalnızca %17.0 seviyesinde kaldı.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Kore'deki 47 üçüncü basamak hastanede ortalama MR güvenliği olgunluk puanı 100 üzerinden 63.08 olarak belirlendi.
  • Ferromanyetik tespit sistemleri (%17.0) ve MRSO ataması (%17.0) konularında uyumluluk düşüktü.
  • Seviye 1 güvenlik eğitimi uyumluluğu yalnızca %23.4'tü.
  • MR prosedürleri için iki kişilik personel sayısı, hafta içi gündüz %97.9'dan tatillerde %38.3'e düştü.
  • %44.7 oranında hastane MR ile ilgili güvenlik olayları bildirdi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

BACKGROUND: MRI safety management is essential for patient safety and for standardizing institutional practices. However, nationwide data on MRI safety readiness in Korean tertiary hospitals remain limited. PURPOSE: To evaluate MRI safety management across all 47 Korean tertiary hospitals and identify major gaps in safety infrastructure, staffing, and education. STUDY TYPE: Cross-sectional census survey. POPULATION: MRI safety managers from all 47 Korean tertiary hospitals in 2025. ASSESSMENT: A structured 50-item questionnaire was developed based on the American College of Radiology (ACR) MRI safety guidelines. A composite safety maturity index (0-100) was calculated as the unweighted arithmetic mean of four domain scores derived from 32 binary safety-practice items, with mandatory items weighted 2 and recommended items weighted 1 in accordance with the 2024 ACR Manual on MR Safety. STATISTICAL TESTS: Descriptive statistics were used to summarize institutional characteristics and safety compliance. Comparisons of staffing patterns by time period were evaluated using inferential tests, with statistical significance set at p < 0.05. RESULTS: The response rate was 100% (47/47). The mean number of MRI units per hospital was 5.32 ± 3.50, and 3.0 T systems were predominant. Compliance was universal for closed-circuit television (CCTV) monitoring and MR Conditional monitoring devices but was low for ferromagnetic detection systems (17.0%), Magnetic Resonance Safety Officer (MRSO) appointment (17.0%), and Level 1 safety education (23.4%). MRI-related safety incidents were reported by 44.7% of hospitals. Two-person staffing decreased significantly from 97.9% on weekday daytime hours to 55.3% on Saturdays, 44.7% at night, and 38.3% on holidays. The overall composite safety maturity score was 63.08 ± 15.04. DATA CONCLUSION: Considerable variability remains in MRI safety management across Korean tertiary hospitals. These findings highlight the need for national MRI safety standards in the Republic of Korea. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 4.

Yazarların özeti; kaynağından alınmıştır. Journal of Magnetic Resonance Imaging, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Acil Sağlık Hizmetleri

Emergency Medical ServicesHealth Professions