Konik Işınlı Bilgisayarlı Tomografi ve Renkli Doppler Ultrasonografi Kullanılarak Mandibular Nütrient Foramina Morfolojik ve Vasküler Değerlendirmesi

Morphological and vascular assessment of mandibular nutrient foramina using cone beam computed tomography and Color Doppler ultrasonography

Menduh Sercan Kaya, Mehmet Emin Dogan, Sedef Kotanlı

Kısa özet

Mandibular nütrient foramina çapı, tespit edilebilir renkli akış sinyallerinin varlığı ile anlamlı derecede ilişkilidir; çapın her 0.1 mm'lik artışı, sinyal tespit olasılığını 5.22 kat artırmaktadır (P < 0.001).

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Nütrient foramina çapı, tespit edilebilir renkli akış sinyalleri ile anlamlı derecede ilişkiliydi (OR = 5.22, P < 0.001).
  • Foramen çapındaki her 0.1 mm'lik artış, renkli akış sinyali tespit etme olasılığını artırdı.
  • KIBT, foraminaların detaylı morfolojik değerlendirmesini sağladı.
  • CDUS, tespit edilebilir renkli akış sinyalleri hakkında tamamlayıcı bilgi sundu.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Abstract One of the anatomical variations found in the mandible is the presence of nutrient foramina. Failure to correctly identify these structures and understand their characteristics may lead to complications during surgical procedures. The aim of this study was to evaluate the presence and morphological characteristics of nutrient foramina using cone beam computed tomography and to assess the presence of detectable colour-flow signals using color Doppler ultrasonography. This observational study consisted of a retrospective cone beam computed tomography assessment of 538 eligible patients, followed by a prospective color Doppler ultrasonography examination of all 45 patients in whom at least one nutrient foramen was identified, comprising a total of 73 nutrient foramina. No statistically significant difference was found in the distribution of nutrient foramina according to sex. A significant association was observed between right- and left-sided nutrient foramen presence ( P < 0.001). In the primary analysis, nutrient foramina diameter analyzed as a continuous predictor was significantly associated with the presence of a detectable colour-flow signal, with each 0.1-mm increase in diameter associated with higher odds of signal detection (OR = 5.22, 95% CI: 2.75–9.93; P < 0.001). Nutrient foramina may be clinically relevant structures. While cone beam computed tomography enables detailed morphological evaluation, color Doppler ultrasonography may provide complementary information regarding detectable colour-flow signals under the applied imaging settings. The combined use of these methods provides complementary morphological and colour-flow information regarding nutrient foramina, while the potential surgical relevance of these findings requires prospective clinical validation.

Yazarların özeti; kaynağından alınmıştır. Scientific Reports, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Ağız Cerrahisi

Oral SurgeryDentistry