Journal of Oral Rehabilitation· 2026Q1
Multi‐Level Automated Classification of Temporomandibular Joint Degenerative Joint Disease on CBCT Using 3D Volumetric and 2D Slice‐Based Approaches
- 0citations
- Q1SCImago
- 2026year
Short summary
A multi-level AI framework using 3D volumetric and 2D slice-based approaches achieved high accuracy in classifying temporomandibular joint degenerative joint disease (TMJ DJD) on CBCT scans, with slice-based detection showing superior performance for specific lesion characterization.
AI-generated from the title and abstract; the full text is not read.
Key points
- A 3D V-Net AI model achieved 79.47% overall sensitivity for classifying TMJ DJD on CBCT scans.
- Condylar volume analysis showed significant differences between TMJ DJD and non-TMJ DJD groups (p = 0.025).
- The slice-based YOLOv10 model achieved 94.0% sensitivity and 82.8% precision for condylar degenerative changes.
- The slice-based YOLOv10 model achieved 92.41% sensitivity and 83.91% precision for articular fossa degenerative changes.
AI-generated from the title and abstract; the full text is not read.
Abstract
ABSTRACT Background Temporomandibular joint degenerative joint disease (TMJ DJD) causes progressive osseous changes of the mandibular condyle and articular fossa. Although cone‐beam computed tomography (CBCT) enables detailed assessment, manual interpretation is time‐consuming and subject to inter‐observer variability. Objectives To develop and validate a multilevel AI framework for CBCT‐based TMJ DJD assessment using three‐dimensional classification, quantitative volumetric analysis, and two‐dimensional slice‐based detection. Methods Full‐field‐of‐view CBCT scans from 222 patients were used for three‐dimensional analysis. A 3D V‐Net classified condyles into Normal, Osteophyte, Erosion, Flattening, and Severe Degeneration categories. Condylar volume was quantitatively compared between TMJ DJD and non‐TMJ DJD groups and among degenerative subgroups. For slice‐based analysis, 727 temporomandibular joints from 416 patients were retrospectively evaluated. Automated sagittal slice extraction based on the condylion landmark generated 5787 condylar and 666 articular fossa slices. YOLOv10 was used for multi‐lesion detection of six condylar and three fossa categories. Results The 3D V‐Net achieved an overall sensitivity of 79.47%. Condylar volume differed significantly between TMJ DJD and non‐TMJ DJD groups (ANOVA, p = 0.025), whereas differences among the TMJ DJD subgroups were not statistically significant. For condylar slice‐based detection, YOLOv10 achieved 94.0% sensitivity, 82.8% precision, 88.0% F1‐score, and 91.3% AP@0.50. For articular fossa detection, YOLOv10 achieved 92.41% sensitivity, 83.91% precision, 87.95% F1‐score, and 82.01% AP@0.50. Conclusions Three‐dimensional AI enabled overall TMJ DJD classification but showed limited discrimination of specific subgroups, particularly erosion. Volumetric analysis differentiated DJD from non‐DJD cases but not among DJD subgroups. In contrast, slice‐based YOLOv10 effectively detected and labelled specific condylar and fossa degenerative changes, providing more detailed lesion‐level characterization.
The authors' abstract, as published at the source. Journal of Oral Rehabilitation, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Oral Surgery
Oral SurgeryDentistry