PofoliaShared via Pofolia

Clinical Trials· 2026Q1

Automated surveillance of primary outcome reporting in clinical trials: Development and validation of a scalable screening pipeline

Hayden Farquhar

Short summary

An automated pipeline successfully screened 46,365 clinical trials for primary outcome reporting discrepancies in under 48 hours, flagging 24.7% for manual review with 100% specificity.

AI-generated from the title and abstract; the full text is not read.

Key points

  • An automated pipeline was developed to screen clinical trial registrations against publications for primary outcome discrepancies.
  • The pipeline processed 46,365 completed interventional trials (2015–2025) in under 48 hours.
  • The system matched 59.4% of trials to publications and flagged 24.7% (3353 trials) for manual review.
  • Validation against manual expert review demonstrated 100% specificity and 16.7% sensitivity.
  • Manual review estimated a true discrepancy rate of 4.9%, primarily minor modifications.

AI-generated from the title and abstract; the full text is not read.

Abstract

Background: Detecting discrepancies between registered and published trial outcomes currently requires manual expert review, limiting surveillance to small samples. No scalable automated system exists for continuous monitoring of outcome reporting integrity across the clinical trial literature. We aimed to develop and validate an automated screening pipeline for primary outcome discrepancies and to characterise its performance at scale. Methods: We developed an automated pipeline that retrieves trial registrations from ClinicalTrials.gov, matches them to publications via PubMed and screens for primary outcome discrepancies using a term-matching algorithm. We applied the pipeline to all 46,365 completed interventional trials with posted results (2015–2025) and validated performance against manual expert review of 123 trial-publication pairs, with independent large language model re-review as a second rater. Results: The pipeline processed 46,365 trials in under 48 h, matching 27,555 (59.4%) to publications and confirming 13,595 pairs via trial identifier verification. Automated screening classified 10,231 (75.3%) as concordant and flagged 3353 (24.7%) for review. Against manual review of 123 pairs, the screen achieved 100% specificity and 16.7% sensitivity (1 of 6 discrepancies); the flag’s positive predictive value could not be estimated because the validation sample contained only one flagged pair. Independent large language model re-review showed 99.2% agreement (Cohen’s kappa = 0.91). Manual review estimated a true discrepancy rate of 4.9% (95% confidence interval = 1.6%–8.9%), predominantly minor modifications (timeframe extensions, operationalisation changes) rather than substantive outcome switching. Automated flag rates were not associated with primary outcome statistical significance (21.0% vs 20.6%; p = 0.745). Discussion: Automated screening can efficiently triage tens of thousands of trials for outcome reporting surveillance, deprioritising 75% of pairs as concordant and concentrating manual review on the flagged subset. The pipeline provides a foundation for continuous, near-real-time monitoring of outcome reporting integrity that could be integrated into journal peer review or regulatory workflows.

The authors' abstract, as published at the source. Clinical Trials, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Statistics, Probability and UncertaintyDecision Sciences