Yapay Zeka Destekli V/Q Sintigrafisinde Vasküler Perfüzyon Defektlerinin Tespit Edilmesi

Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism

Amir Jabbarpour, Eric Jr Moulton, Sanaz I. Kaviani, Siraj Ghassel ve diğerleri

Kısa özet

Bir Darboğaz Transformatör U-Net (BTU-Net) yapay zeka modeli, pulmoner emboli tanısı için ventilasyon/perfüzyon (V/Q) sintigrafisindeki vasküler perfüzyon defektlerini tespit etmede insan okuyucu performansına eşdeğer bir performans göstererek, projeksiyon başına 1.5 yanlış pozitifte 0.529 duyarlılık elde etti.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Düzlemsel V/Q taramalarındaki vasküler perfüzyon defektlerinin otomatik segmentasyonu için bir Darboğaz Transformatör U-Net (BTU-Net) yapay zeka modeli geliştirildi.
  • BTU-Net, projeksiyon başına 1.5 yanlış pozitif oranında 0.529 ± 0.026 duyarlılık ile insan düzeyinde performans göstererek diğer yapay zeka modellerini geride bıraktı.
  • Model ayrıca düşük olasılıklı hasta setinde 0.08 ± 0.01 gibi düşük bir yanlış pozitif oranı sergiledi.
  • Yapay zeka modeli 1.313 hastadan oluşan bir veri seti üzerinde eğitildi ve 329 hastadan oluşan bir veri seti üzerinde doğrulandı; performansı 46 yüksek olasılıklı hasta içeren bir test setinde değerlendirildi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

OBJECTIVE: Accurate interpretation of planar ventilation-perfusion (V/Q) scintigraphy, used for diagnosing pulmonary embolism (PE) based on PIOPED/EANM guidelines, requires objective assessment of mismatched V/Q defects. Manual delineation of V/Q defects is time-consuming, subject to interobserver variability, and rarely performed in practice, limiting standardized reporting and quantification of disease burden. To address these challenges, we evaluated four modern AI models for automated segmentation of vascular perfusion defects in planar V/Q scans and compared their performance to human annotators. APPROACH: We retrospectively identified 2,118 patients who underwent planar V/Q scans at The Ottawa Hospital (June 2019-February 2023). Six standard projections (ANT, POST, LAO, RAO, LPO, RPO) were included. Four 2D neural networks (U-Net, nnU-Net, Swin UNETR, and a Bottleneck Transformer U-Net [BTU-Net]) were trained on 1,313 patients (7,878 projections) and validated on 329 (1,974 projections) using physician-annotated defects. A hold-out test set of 46 high probability patients was used to evaluate segmentation quality, and defect detection accuracy using free-response receiver operating characteristic (FROC) analysis. MAIN RESULTS: BTU-Net was the only model performing on par with human readers, showing robust sensitivity across the entire range of segmentation probabilities. At 1.5 false positives per projection rate (FPPR), BTU-Net outperformed other models with sensitivity of 0.529 ± 0.026, On a separate hold-out set of low likelihood of disease patients (n=430), the lowest FPPR was 0.08 ± 0.01 for BTU-Net (P<0.0001). SIGNIFICANCE: BTU-Net enables rapid, consistent, and accurate interpretation of planar V/Q scans. Such tools may enhance diagnostic efficiency, standardize reporting, and support non-expert readers in evaluating PE.

Yazarların özeti; kaynağından alınmıştır. Physics in Medicine and Biology, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Bilgisayarlı Görü ve Örüntü Tanıma

Computer Vision and Pattern RecognitionComputer Science