Hibrit Yenilenebilir Enerji Sisteminde Pompaj Depolamalı Hidroelektrik, Tuzdan Arındırma İçin Pilleri Geride Bıraktı

Comparative assessment of pumped hydro and battery storage in a hybrid renewable energy system with excess-energy-driven desalination

A.S.M. Shahriar Rahman, Saifa Siddika, Asif Jaman, Md. Emdadul Hoque ve diğerleri

Kısa özet

Pompaj depolamalı hidroelektrik (PHS) depolamalı hibrit yenilenebilir enerji sistemi, lityum demir fosfat (LFP) pilli sisteme göre uzaktaki bir topluluğu ve tuzdan arındırma tesisini beslemede daha üstün olup, daha düşük enerji maliyeti (0,2452 $/kWh) ve daha yüksek güvenilirlik (%4,928 güç kesintisi olasılığı) sağlamıştır.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Pompaj depolamalı hidroelektrik (PHS), uzaktaki bir topluluk için hibrit yenilenebilir sistemde birinci sırada yer alarak LFP pillerini geride bırakmıştır.
  • Optimal PHS sistemi 0,2452 $/kWh enerji maliyeti ve %4,928 güç kesintisi olasılığına ulaşmıştır.
  • PHS sistemleri, yılda 62.154,82 m³ tatlı su üreterek tuzdan arındırma için fazla enerjinin %57,77'sini kullanmıştır.
  • Daha düşük yuvarlak-trip verimliliğine rağmen, PHS'nin LFP pillere kıyasla yaşam döngüsü emisyonları önemli ölçüde daha düşüktür.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Off grid renewable systems on remote coasts lean on storage to bridge long spells of weak solar and wind, yet mechanical and electrochemical storage are rarely tested side by side under the same conditions. This work assesses seawater pumped hydro storage (PHS) and lithium iron phosphate (LFP) batteries inside a standalone system for Rangabali, Bangladesh, and routes surplus renewable energy that would otherwise be dumped into a reverse osmosis plant treated as a priority-dispatched, shiftable load. Both options were sized for the same community and water loads under cycle charging and load following dispatch using NSGA-II, NSGA-III, MOGWO, and MOSSOA, then ranked by a two stage Fuzzy TOPSIS framework on cost, lifecycle emissions, reliability, excess energy utilization, and job creation. The PV/WT/DG/PHS configuration under load following dispatch ranked first with a cost of energy of 0.2452 $/kWh and a loss of power supply probability of 4.928% while supplying 2821.6 MWh of electricity per year. Holding the diesel generator to 894 h/year kept lifecycle emissions at 0.1632 × 10 6 kg of CO₂ equivalent per year, a 97% cut against a conventional baseline, and 272.24 MWh/year of surplus produced 62,154.82 m 3 of freshwater; the RO plant and storage together used 57.77% of all surplus generation (excess energy utilization factor). The LFP bank recovered energy at 95% round trip efficiency against 70% for PHS, but its 15-year life and heavy embodied carbon left its own storage-related emissions nearly 50 times above PHS's, even though whole-system lifecycle emissions differed by less than a factor of two between the top-ranked configuration of each technology. A Monte Carlo analysis of 10,000 runs returned a mean cost of energy of 0.2031 $/kWh with narrow dispersion when demand was sampled 10% to 50% above the design load with capacity held fixed.

Yazarların özeti; kaynağından alınmıştır. Journal of Energy Storage, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Enerji Mühendisliği ve Güç Teknolojisi

Energy Engineering and Power TechnologyEnergy