PofoliaGünlük literatür takibi

European Archives of Oto-Rhino-Laryngology· 2026Q1

Kronik otitis media sekellerine bağlı mikst tipi işitme kaybında işitsel rehabilitasyon: pasif transkutan kemik iletimli implantlara karşı aktif transkutan kemik iletimli implant

Auditory rehabilitation in mixed hearing loss due to chronic otitis media sequelae: passive versus active transcutaneous bone conduction implant

Leonardo Elías Ordóñez Ordóñez, María Laura Rojas Serrano, José Agustín Caraballo, Francisco Javier González-Eslait ve diğerleri

Kısa özet

Aktif transkutan kemik iletimli implantlar (AT-BCI), kronik otitis media sekellerinden kaynaklanan mikst tipi işitme kaybı olan hastalarda hem ortalama hem de yüksek frekans saf ses ortalamaları (PTA ve HF-PTA) için klinik olarak anlamlı işitsel kazanç sağlar ve yüksek frekanslarda pasif cihazlara (PT-BCI) göre üstünlük gösterir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Hem AT-BCI hem de PT-BCI, kronik otitis media sekellerinden kaynaklanan mikst tipi işitme kaybı olan hastalarda saf ses ortalamalarını (PTA) ve yüksek frekans saf ses ortalamalarını (HF-PTA) önemli ölçüde iyileştirdi.
  • AT-BCI, HF-PTA (F(1,320)=5.665, p=0.018) ve PTA (F(1,321)=5.317, p=0.022) için PT-BCI'ye göre istatistiksel olarak anlamlı bir avantaj gösterdi.
  • AT-BCI ile elde edilen klinik olarak anlamlı işitsel kazançlar 3. ay gibi erken bir sürede gözlemlendi ve 12. ayda da korundu.
  • Hastaların %88.2'si COSI ölçeğinde iyileşmiş performans bildirdi; AT-BCI ve PT-BCI grupları arasında anlamlı bir fark gözlenmedi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Abstract Purpose : To compare audiological outcomes and self‑perceived benefits in patients with sequelae of chronic otitis media (COM) and mixed hearing loss (MHL) undergoing rehabilitation with either a passive transcutaneous bone conduction implant (PT-BCI) or an active transcutaneous bone conduction implant (AT-BCI). Methods A multicenter, prospective and observational analytical study in Colombia included patients receiving PT‑BCI or AT‑BCI. Main outcomes were pure‑tone average (PTA=0.5-4Khz), high‑frequency PTA (HF‑PTA=4–8 kHz), and Client Oriented Scale of Improvement (COSI). Comparative analyses used two‑way repeated‑measures ANOVA (complete‑case) followed by linear mixed‑effects models for repeated measures (LMMs‑RM) to address group imbalance and missing postoperative data, thereby optimizing statistical power. Results A total of 211 AT‑BCI and 50 PT‑BCI patients were included. Baseline characteristics were comparable, except for soft‑tissue thickness. Both devices achieved significant improvements in PTA and HF‑PTA at 3 and 12 months (p<0.010). LMMs‑RM confirming significant effects of device type and time for both outcomes: for PTA (Type of device: F (1,321 )=5.317, p=0.022; Time: F (2,321) =201.179, p<0.001) and for HF‑PTA (Type of device: F (1,320) =5.665, p=0.018; Time: F (2, 320) =116.934, p<0.001). 82 patients (88.2%) reported that their performance with the device was “Better”/“Much better” on the COSI scale, no statistically significant differences observed between the AT‑BCI and PT‑BCI groups (p=0.283). Conclusions AT‑BCI provides a clinically meaningful auditory gain in both PTA and HF‑PTA in patients with MHL secondary to COM. This level of audiological performance is achieved as early as the 3‑month follow‑up and is maintained over time, while remaining superior for HF-PTA to that obtained with PT‑BCI.

Yazarların özeti; kaynağından alınmıştır. European Archives of Oto-Rhino-Laryngology, 2026 · DOI ↗

ÇıkarımlarPremium Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 5 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Kulak Burun Boğaz

OtorhinolaryngologyMedicine