PofoliaGünlük literatür takibi

PLOS Digital Health· 2026Q1

Koroner mikrovasküler fizyolojinin invaziv anjiyografi kaynaklı hesaplamalı modelinin sürekli termodilüsyona göre uyumu

Agreement of an invasive angiography-derived computational model of coronary microvascular physiology against continuous thermodilution

Daniel Taylor, Tom Newman, Karolina Tlałka, Eron Yones ve diğerleri

Kısa özet

İnvaziv koroner anjiyografiden türetilen yeni bir 3B hesaplamalı akışkanlar dinamiği (CFD) modeli, sürekli termodilüsyona (CIT) kıyasla mikrovasküler direnç rezervi (MRR) değerlendirmesinde orta düzeyde korelasyon (ρ = 0.58) ve makul düzeyde tanısal doğruluk (AUC = 0.77) göstermiştir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • İnvaziv koroner anjiyografi verileri kullanılarak mikrovasküler direnç rezervi (MRR) ve mutlak akışı değerlendirmek için bir 3B CFD modeli geliştirildi.
  • CFD modeli, MRR (ρ = 0.58) ve akış (ρ = 0.44) için sürekli termodilüsyona (CIT) kıyasla orta düzeyde bir korelasyon gösterdi.
  • CFD modelini kullanarak MRR sınıflandırması için tanısal doğruluk makul düzeydeydi (AUC = 0.77).
  • MRR ve akışın daha düşük, klinik olarak daha ilgili değerleri için CFD ve CIT arasındaki uyum iyileşti.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Coronary microvascular dysfunction is associated with myocardial ischaemia and an adverse prognosis, but accurate invasive assessment is technically challenging, requires dedicated hardware and increases procedure time and cost. Assessment can be performed with three-dimensional (3D) computational fluid dynamics (CFD) modelling, but this technique lacks robust in vivo validation. In this study, we compared the accuracy of a 3D CFD method against continuous thermodilution (CIT). Patients with acute and chronic coronary syndromes, undergoing CIT and angiography-derived assessment, were prospectively recruited from two tertiary cardiac centres. Invasive coronary angiographic images were used to reconstruct 3D anatomy in silico. Microvascular resistance reserve (MRR) and absolute flow were computed using 3D CFD in reconstructed coronary arteries. Invasive pressure measurements, recorded during fractional flow reserve assessment, informed the CFD boundary conditions. Paired flow results were available for 131 arteries from 89 patients. Median FFR was 0.81 [0.70 - 0.89] and 108 (81%) vessels contained an epicardial stenosis. Median computed MRR was 2.31 [1.83 - 3.00], which was significantly lower than CIT assessed MRR (2.79 [2.21 - 3.52], z = 3.57, p = 0.0004). There was evidence of a moderate relationship between computed and measured MRR (ρ = 0.58, p < 0.0001) and area under the receiver operator characteristic curve was 0.77 (95% CI 0.68-0.86), indicating fair classification. There was a moderate relationship between computed and measured hyperaemic vessel inlet flow (ρ = 0.44, p < 0.0001). For both MRR and flow, agreement improved at lower, more clinically relevant, values. In this clinical validation study, when compared with CIT, the novel CFD method demonstrated a moderate correlation, and fair diagnostic accuracy. This CFD method may be a useful, low-cost and less-invasive tool in the assessment of microvascular physiology that could complement current invasive techniques.

Yazarların özeti; kaynağından alınmıştır. PLOS Digital Health, 2026 · DOI ↗

ÇıkarımlarPremium Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 5 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Kardiyoloji ve Kardiyovasküler Tıp

Cardiology and Cardiovascular MedicineMedicine