Bilgisayarlı Tomografi Tabanlı Üç Boyutlu Proksimal Femur Morfometrisinin Kuru Kadavra Femurlarında Raterler Arası Güvenilirliği, Uyumu ve Ölçüm Hatası

Inter-rater reliability, agreement and measurement error of CT-based three-dimensional proximal femoral morphometry in dry cadaveric femora

Mohammad Imad Awad Ghannam, Nur Arfian, Arif Faisal, Yudha Mathan Sakti

Kısa özet

BT tabanlı 3B morfolojisi, altı lineer boyut ve distal kanal çapı (FCD2) için mükemmel raterler arası güvenilirlik (ICC 0.936–0.995) gösterirken, femur anteversiyonu (FAA; ICC 0.676) ve proksimal kanal çapı (FCD1; ICC 0.705) için orta düzeyde güvenilirlik göstermektedir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Proksimal femurun altı lineer boyutu ve distal kanal çapı (FCD2), mükemmel raterler arası güvenilirlik (ICC 0.936–0.995) göstermektedir.
  • Femur anteversiyonu (FAA) ve proksimal kanal çapı (FCD1), orta düzeyde raterler arası güvenilirlik (sırasıyla ICC 0.676 ve 0.705) sergilemektedir.
  • FAA (4.55°), FCD1 (1.13 mm) ve FCD2 (0.49 mm) için raterler arasında anlamlı sistematik farklılıklar gözlemlenmiştir.
  • Femur anteversiyonu (FAA), 4.90° SEM ve -9.0° ila +18.2° uyum sınırları ile en büyük ölçüm hatasına sahiptir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Abstract Computed tomography (CT)-based three-dimensional (3D) morphometry is widely used to describe the proximal femur, yet the measurement properties of individual parameters are rarely reported. We quantified the inter-rater reliability, agreement and measurement error of ten proximal femoral parameters measured independently by two blinded raters on 3D models of 20 adult dry cadaveric femora. Reliability was quantified with the intraclass correlation coefficient [ICC(2,1)], measurement error with the standard error of measurement (SEM) and minimal detectable change, and agreement and systematic bias with Bland–Altman analysis and paired t-tests. Six linear dimensions and the distal canal diameter (FCD2) showed excellent reliability (ICC 0.936–0.995; SEM 0.32–1.31 mm). The neck-shaft angle showed good reliability (ICC 0.778), and femoral anteversion (FAA; ICC 0.676) and the proximal canal diameter (FCD1; ICC 0.705) moderate reliability. Significant systematic differences between raters occurred for FAA (4.55°), FCD1 (1.13 mm) and FCD2 (0.49 mm), the latter despite excellent reliability. FAA had the largest measurement error (SEM 4.90°; limits of agreement − 9.0° to + 18.2°). These results describe agreement between two raters under one protocol; they do not establish anatomical accuracy, which requires comparison with a reference standard.

Yazarların özeti; kaynağından alınmıştır. Scientific Reports, 2026 · DOI ↗

ÇıkarımlarPremium Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 5 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Statistics, Probability and UncertaintyDecision Sciences