Environmental Science and Pollution Research· 2026Q1
Organik yükleme etkilerinin entegre dikey akışlı tasarlanmış sulak alan–çift filtrasyon sisteminde fizikokimyasal performans ve metal zayıflatma üzerindeki etkileri
Organic loading effects on physicochemical performance and metal attenuation in an integrated vertical flow constructed wetland–double filtration system
- 0atıf
- Q1SCImago
- 2026yıl
Kısa özet
Entegre bir dikey akışlı tasarlanmış sulak alan (VFCW) ve ardından çift filtrasyon (DF) sistemi, organik maddeyi (KOİ ≥ %87,7, BOİ ≥ %91,0) ve metalleri etkili bir şekilde giderdi, ancak performans artan organik yükleme oranlarında (25,0 ila 91,8 g KOİ/m²·gün) azaldı. Metal giderme verimlilikleri, düşük yüklemede %90'ın üzerinde iken yüksek yüklemede %60-75'e düştü.
Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.
Ana noktalar
- Entegre VFCW–DF sistemi, test edilen organik yükleme oranlarında yüksek KOİ (≥ %87,7) ve BOİ (≥ %91,0) giderimi sağladı.
- Organik yükleme arttıkça bulanıklık giderimi %94,3'ten %63,1'e düştü.
- Metal giderme verimlilikleri, daha yüksek organik yüklerle birlikte tanımlayıcı olarak azaldı: Cd (%90,3 ila %75,7), Pb (%94,0 ila %75,0), Cr (%90,4 ila %70,9), Ni (%91,8 ila %60,4) ve Cu (%92,5 ila %74,4).
- pH hariç fizikokimyasal değişkenler ve beş metal için önemli arıtma aşaması farklılıkları gözlemlendi.
Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.
Özet (abstract)
Abstract Vertical flow constructed wetlands coupled with filtration can provide compact post-treatment of anaerobic effluents, but their performance under variable organic loading remains insufficiently characterized. A pilot-scale vertical-flow constructed wetland followed by coagulant-free double filtration was evaluated using upflow anaerobic sludge blanket effluent fortified with cadmium, lead, chromium, nickel, and copper under organic loading rates of 25.0, 44.0, and 91.8 g COD/m 2 · d. Physicochemical variables and metal concentrations were monitored at the UASB, VFCW, and final double-filtration stages. Chemical oxygen demand and biochemical oxygen demand removal efficiencies remained at least 87.7% and 91.0%, respectively, whereas turbidity removal decreased descriptively from 94.3% to 63.1% across the sequential loading gradient. Metal removal efficiencies also declined descriptively from the lowest- to the highest-loading condition: Cd from 90.3% to 75.7%, Pb from 94.0% to 75.0%, Cr from 90.4% to 70.9%, Ni from 91.8% to 60.4%, and Cu from 92.5% to 74.4%. Friedman tests indicated significant treatment stage differences for all evaluated physicochemical variables except pH and for all five metals. An integrated block-balanced partial redundancy analysis (pRDA), conditioned on sampling event, revealed a strong treatment stage effect (partial R 2 = 0.898, pseudo- F = 70.33, p = 0.0001). Overall, the integrated VFCW–DF system provided effective organic matter removal and progressive metal attenuation, while the descriptive loading patterns indicated lower clarification and metal retention performance under the highest-loading condition. The system represents a compact post-treatment alternative for decentralized wastewater polishing and reuse.
Yazarların özeti; kaynağından alınmıştır. Environmental Science and Pollution Research, 2026 · DOI ↗
Ücretsiz hesapla devam et
Makaleye Sor ile bu makaleye günde 5 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.
Web'de ücretsiz devam etGoogle ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.
Telefonda:
Waste Management and DisposalEnvironmental Science