Lösemi İlişkili Translokasyon Genlerinin Tespiti İçin Multiplex Gerçek Zamanlı Polimeraz Zincir Reaksiyonu Deneyi Geliştirilmesi

Development of multiplex real-time polymerase chain reaction assay for the detection of leukemia-associated translocation genes

Zi-Qi Lin, Cheng-Hao Wu, Tzu-Lin Chen, Tzu-Chun Lin ve diğerleri

Kısa özet

Yedi yaygın lösemi ilişkili kromozomal translokasyonu (TCF3::PBX1, ETV6::RUNX1, PML::RARA, KMT2A::AFF1, BCR::ABL1, CBFB::MYH11 ve RUNX1::RUNX1T1) aynı anda saptayabilen bir multiplex gerçek zamanlı PCR deneyi geliştirildi; ortalama tespit limiti 10^4 kopya/mL olarak belirlendi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Yedi spesifik lösemi translokasyon gen füzyonunu tespit etmek için bir multiplex gerçek zamanlı PCR deneyi geliştirildi.
  • Deney, yaklaşık 10^4 kopya/mL ortalama tespit limitine ve yüksek özgüllüğe ulaştı.
  • Klinik örnekler ve sentetik kontroller kullanılarak doğrulandı, doğruluğu teyit edildi.
  • PML::RARA (bcr3) translokasyonu, protokol optimizasyonuna ihtiyaç olduğunu gösteren suboptimal floresans gösterdi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

A BSTRACT Objective: Leukemia diagnosis involves diverse methods, including cytomorphology, flow cytometry, cytogenetics, and molecular diagnostics. While cytogenetics plays an indispensable role, it is limited by a high false-negative rate. In contrast, molecular diagnostics, such as real-time polymerase chain reaction (PCR), have become practical and widely used in clinical settings. This study aims to establish a multiplex real-time PCR system to detect critical leukemia-related chromosomal translocations, encompassing seven genes and 12 mutation types. Materials and Methods: Bioinformatics tools were employed for nucleic acid sequence analysis and primer design using reference sequences from NCBI and COSMIC databases. Primers were designed to flank frequent breakpoints. Performance testing involved gradient temperature PCR to optimize conditions and establish detection limits. A multiplex system was configured into six reaction tubes using a Rotor-Gene Q analyzer. Specific sequence plasmids were synthesized as quality control standards. Results: A successful multiplex real-time PCR system was established to detect translocations including TCF3::PBX1, ETV6::RUNX1, PML::RARA, KMT2A:: AFF1, BCR::ABL1, CBFB::MYH11, and RUNX1::RUNX1T1 . The assay demonstrated an average detection limit of approximately 10 4 copies/mL with high specificity. Validation using clinical specimens and synthetic controls confirmed the system’s accuracy, although PML::RARA (bcr3) showed suboptimal fluorescence requiring protocol optimization. Conclusion: This multiplex detection system provides comprehensive genetic information and reduces turnaround time compared to traditional cytogenetic methods. It offers significant clinical benefits for the initial workup and disease monitoring of leukemia patients.

Yazarların özeti; kaynağından alınmıştır. Tzu Chi Medical Journal, 2026 · DOI ↗