PofoliaPofolia ile paylaşıldı

Biomaterial Investigations in Dentistry· 2026Q2

Bakteriyel Maruziyet NiTi Açık Spiral Yayların Kuvvetini Değiştirir, Markaya Özgü Etkilerle

Impact of bacterial exposure on the mechanical behavior of nickel–titanium open-coil springs

Diego Paul Hidalgo Muñoz, Mauricio Aguirre Balseca, Marjory Elizabeth Vaca Zapata, KARINA MARIA SALVATORE FREITAS ve diğerleri

Kısa özet

Streptococcus mutans'a 30 gün boyunca maruz kalmak, nikel-titanyum (NiTi) açık spiral yayların kuvvet çıkışını önemli ölçüde değiştirmiş olup, Ormco ve American Orthodontics gibi markalar 3M'e kıyasla daha belirgin ve tahmin edilemez değişiklikler (bazı durumlarda %80 gf'nin üzerinde kuvvet artışı) göstermiştir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • 30 günlük Streptococcus mutans inkübasyonu, test edilen tüm NiTi açık spiral yay markalarında kuvvet seviyelerini değiştirmiştir.
  • 3M yayları, hem kontrol hem de bakteriyel koşullar altında yer değiştirmeler boyunca nispeten kararlı kuvvet artışları göstermiştir.
  • American Orthodontics yayları, özellikle bakteriyel maruziyet sonrası kuvvet kayıpları ve kazançları ile düzensiz yanıtlar sergilemiştir.
  • Ormco yayları, mikro yapısal değişiklikler düşündüren, 80 gf'yi aşan en yüksek değişkenliği ve en belirgin kuvvet artışlarını sergilemiştir.
  • Marka bağımlılığı ve bakteriyel etki, NiTi yay kuvvet kararlılığını etkileyen kritik faktörlerdir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Objective: This in vitro study aimed to evaluate the effect of Streptococcus mutans on the force alteration of nickel–titanium (NiTi) open-coil springs under constant compression. Materials and methods: Sixty NiTi open-coil springs from three commercial brands (3M, Ormco, and American Orthodontics [AO]) were standardized to a resting length of 15 mm and compressed with a 240-g load using an Instron® universal testing machine. Each brand was divided into control (immersed in artificial saliva) and experimental (exposed to S. mutans in Brain Heart Infusion medium) conditions. Samples were incubated at 37°C for 30 days, after which force levels at 0.5, 3.25, and 6.5 mm displacements were remeasured. Data were analyzed with paired t-tests, one-way analysis of variance, and Tukey’s post hoc tests (p < 0.05).Results: All brands exhibited force increases after 30 days, though with heterogeneous patterns. 3M springs maintained relatively stable behavior, with consistent force increments across all displacements in both conditions. AO springs showed irregular responses, with losses at some displacements and substantial gains at others, especially under bacterial exposure. Ormco springs displayed the highest variability and most pronounced increases, with force gains exceeding 80 gf, suggesting possible microstructural modifications.Conclusions: Force stability in NiTi open-coil springs is brand-dependent and influenced by bacterial exposure. While 3M springs demonstrated predictable performance, AO and Ormco exhibited less consistent behavior, which may risk excessive force application during clinical use. These findings highlight the importance of considering biological and environmental factors in the selection and monitoring of NiTi coil springs.

Yazarların özeti; kaynağından alınmıştır. Biomaterial Investigations in Dentistry, 2026 · DOI ↗

ÇıkarımlarUygulamada
Makaleye SorUygulamada

Devamı Pofolia uygulamasında

Çıkarımlar ve makaleye soru sorma; ilgi alanına göre her gün yeni özetler. Ücretsiz.

Web'de giriş yaparak aç

Alan: Ortodonti

OrthodonticsDentistry