PofoliaPofolia ile paylaşıldı

Analytical Chemistry· 2026Q1

Dapson ve Kotrimoksazol Kaynaklı Ciddi Kutanöz Yan Etkileri (SCAR'ları) Önlemek İçin HLA-B*13:01 Tespiti İçin Elektrokimyasal Çift Algılama Platformu

Electrochemical Dual-Sensing Platform for HLA-B*13:01 Detection to Prevent Severe Cutaneous Adverse Reactions (SCARs) Induced by Dapsone and Cotrimoxazole

Jirapat Attapong, Chollanot Kaset, Nontaya Nakkam, Wichittra Tassaneeyakul ve diğerleri

Kısa özet

Taşınabilir bir elektrokimyasal çift algılama platformu (EDP), HLA-B*13:01 ve TIMP-1 kontrolünü eşzamanlı olarak tespit ederek, 65,5 fg (CV) ve ~3 HLA-B gen kopyası kadar düşük tespit limitlerine ulaşır ve klinik örneklerde %100 doğruluk sağlar.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • HLA-B*13:01 ve TIMP-1'in eşzamanlı tespiti için taşınabilir bir elektrokimyasal çift algılama platformu (EDP) geliştirildi.
  • 65,5 fg (CV) ve ~3 HLA-B gen kopyası gibi ultrasensitif tespit limitlerine ulaşıldı.
  • Sinyal iyileştirmesi için diziye özgü ssDNA hibritizasyonu ve metilen mavisi modülasyonu kullanıldı.
  • 100 körlenmiş klinik örnek üzerinde doğrulanan platform, %100 duyarlılık, özgüllük ve doğruluk elde etti.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Abstract The HLA-B*13:01 allele is a critical biomarker for dapsone- and cotrimoxazole-induced severe cutaneous adverse reactions (SCARs). Overcoming the limitations of centralized laboratory screening, we developed a portable electrochemical dual-sensing platform (EDP) for the simultaneous, ultrasensitive detection of HLA-B*13:01 alongside a TIMP-1 internal control. On screen-printed carbon electrodes (SPCEs), TIMP-1 is captured through robust biotin–streptavidin interactions, while HLA-B*13:01 relies on sequence-specific ssDNA hybridization. Crucially, the system utilizes methylene blue (MB) to precisely modulate both electrostatic repulsion and physical steric hindrance, enhancing signal discrimination. The platform demonstrates exceptional limits of detection, reaching 0.992 pg and 65.5 fg when evaluated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), respectively. Notably, accounting for genomic copy number, this corresponds to a practical detection limit of ∼3 HLA-B gene copies (1 × 10–2 ng genomic DNA), several orders of magnitude below conventional gel electrophoresis. Validated against 100 blinded clinical samples, the EDP achieved 100% sensitivity, specificity, and accuracy using ROC-derived cut-offs. By delivering a highly scalable, portable post-PCR screening tool, this work provides a high-performance alternative to standard methods, effectively mitigating SCAR risks and advancing the global accessibility of precision medicine.

Yazarların özeti; kaynağından alınmıştır. Analytical Chemistry, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Farmakoloji (Tıp)

PharmacologyMedicine