PofoliaPofolia ile paylaşıldı

Journal of Robotic Surgery· 2026Q1

Tek portlu, orta hat yaklaşımıyla Robotik Transaksiller Tiroidiidektomi (SMART-Tiroidiidektomi): tekniğin tanımı ve ilk olgu serisinde fizibilite değerlendirmesi

Single-port, via a midline approach, Robotic Transaxillary Thyroidectomy (SMART-Thyroidectomy): description of the technique and evaluation of feasibility in the first case series

Marco Raffaelli, Pierpaolo Gallucci, Ilda Hoxhaj, Francesco Pennestrì

Kısa özet

Yeni bir Tek insizyonlu, Orta Hat Yaklaşımıyla Robotik Transaksiller Tiroidiidektomi (SMART-T) tekniği, 16 hastada başarıyla gerçekleştirildi ve mükemmel kozmetik sonuçlarla (%87,5 mükemmel olarak derecelendirilmiş) tek bir aksiller insizyondan orta hat operatif görüşü sağladı.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Tek portlu robotik transaksiller tiroidiidektomi olan SMART-T, 16 hastada başarıyla gerçekleştirildi.
  • Teknik, tek bir aksiller insizyondan orta hat operatif görüşü sağlar.
  • Ortalama operasyon süresi 99,6 dakika olup, minimal komplikasyonlar ve bir hastada geçici vokal kord hipomobilitesi gözlemlendi.
  • Hastaların %87,5'i mükemmel kozmetik sonuçlar bildirdi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

The Da Vinci SP system has recently been applied to remote-access robotic thyroidectomy, enabling single-port (SP) surgery with enhanced instrument articulation. We evaluated the feasibility of a novel Single-incision, via a Midline Approach, Robotic Transaxillary Thyroidectomy (SMART-T), which combines the cosmetic advantages of a concealed axillary incision with the bilateral midline exposure provided by the bilateral axillo-breast approach (BABA). A prospective analysis was performed on an initial series of patients who underwent SMART-T between June and July 2026. Demographic, operative, pathological, and postoperative data were collected. Sixteen patients successfully underwent SMART-T without conversion. All patients underwent lobo-isthmusectomy (11 right-sided and 5 left-sided procedures). Mean operative time was 99.6 ± 17.5 min, with mean docking and console times of 5.1 ± 2.0 and 55.6 ± 17.7 min, respectively. Ipsilateral central neck dissection was completed in three patients. One patient experienced transient minimal vocal cord hypomobility that resolved within 7 days. No other complication occurred. Postoperative pain and analgesic requirements were minimal. Subjective voice and swallowing impairment were minimal and completely recovered by postoperative day 7. Cosmetic outcomes were rated as excellent by 87.5% of patients. The present study reports the first European clinical series of SP BABA-derived thyroid procedures. SMART-T is a feasible single-port robotic approach to thyroidectomy that provides a BABA-like midline operative view through a single axillary incision, with encouraging early operative, functional, and cosmetic outcomes that support further evaluation in larger studies with longer follow-up.

Yazarların özeti; kaynağından alınmıştır. Journal of Robotic Surgery, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Cerrahi

SurgeryMedicine