PofoliaPofolia ile paylaşıldı

Scientific Reports· 2026Q1

70 MW CFBC kazanlarının süper-ısıtıcı borularının GTA ve SMA kaynaklı erimiş tuz sıcak korozyonu üzerine karşılaştırmalı bir inceleme

A comparative investigation on molten salt hot corrosion of GTA and SMA-welded super-heater pipes of 70 MW CFBC boilers

Leyander Reginald Pillai, A. Aravind, R. V. Dhanushwaran, S. K. Praveen ve diğerleri

Kısa özet

ERNiCrMo-3 dolgu malzemesi, GTAW ile kullanıldığında, 770°C'de Na2SO4 + %60 V2O5 erimiş tuzu ile maruz kalan SA 335 P91 süper-ısıtıcı borularında, E9018 B9 dolgu malzemesine (SMAW) kıyasla üstün sıcak korozyon direnci göstermiştir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • ERNiCrMo-3 dolgu malzemesi (GTAW), SA 335 P91 süper-ısıtıcı borularında E9018 B9 dolgu malzemesine (SMAW) kıyasla üstün sıcak korozyon direnci sergilemiştir.
  • Üstün direnç, ERNiCrMo-3 kaynaklı numunelerde koruyucu bir NiFe2O4 spinel oksit tabakasının oluşumuna bağlanmaktadır.
  • E9018 B9 kaynak bölgeleri kabarcıklanma yaşamış ve erimiş tuz korozyonuna karşı daha savunmasız bulunmuştur.
  • Korozyon testleri, 50 çevrim boyunca Na2SO4 + %60 V2O5 erimiş tuzu kullanılarak 770 ± 1°C'de gerçekleştirilmiştir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

Abstract The tubular SA 335 P91 joints are generally used as super-heater pipes in CFBC boilers. This research work presents hot corrosion studies on similar SA 335 P91 joints using ErNiCrMo-3 and E9018 B9 fillers via GTAW and SMAW. The HTC studies were conducted at 770 ± 1˚C employing Na 2 SO 4 +60% V 2 O 5 molten salt mixture on parent metal (PM) and GTA and SMA-weldments with 50 cycles. To predict the corrosion kinetics, TGA were generated. The layer of oxide formed on the surface of weldments and PM has been methodically described using SEM/EDS. The phases of oxide layers were examined through XRD analysis. The investigation confirms that the Ni-rich filler fusion zone coupon exhibits superior oxidation resistance due to the formation of spinel oxide (NiFe 2 O 4 ), which acts as a protective barrier against the penetration of corrosive species. The cross-sectional SEM image and XRD results confirmed that the thin scale formed on the oxidized weldments which were well adherent with the substrate. Blistering was experienced at the E9018 B9 weld zone and found to be more vulnerable to degradation. Consequently, ERNiCrMo-3 filler is recommended for joining similar joints of P91 metals employing the GTAW process used in CFBC boilers.

Yazarların özeti; kaynağından alınmıştır. Scientific Reports, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla