Short summary
A Smart Archival Box prototype, combining active thermoelectric cooling with passive ArtSorb and filtration, maintained target temperatures (17.5–18.5 °C) for 79.7% of a 2.8-hour test simulating environmental fluctuations, while reducing PM2.5 and TVOC exposure by over 94%.
AI-generated from the title and abstract; the full text is not read.
Key points
- The Smart Archival Box prototype integrates thermoelectric modules, ArtSorb, and filtration for microclimate control.
- In a 2.8-hour test simulating environmental shifts, the hybrid system maintained a tight 17.5–18.5 °C band for 79.7% of the time.
- The system reduced PM2.5 and TVOC levels by 98.4% and 94.4%, respectively.
- Electrical consumption for hybrid and active modes was similar (0.05177 kWh vs. 0.05156 kWh), significantly higher than passive mode (0.00565 kWh).
AI-generated from the title and abstract; the full text is not read.
Abstract
Museum and archive storage facilities worldwide face persistent difficulties in maintaining stable microclimatic conditions. This study presents a Smart Archival Box, a modular hardware–software system for preventive conservation, together with a model-based evaluation of its microclimate control. The numerical domain has a nominal volume of 0.125 m3 (0.5 m × 0.5 m × 0.5 m) and combines a 1 kg ArtSorb cassette, four TEC1-12706 thermoelectric modules, particulate/activated-carbon filtration, distributed monitoring and RFID-based access control. Temperature is regulated by a single proportional–integral–derivative (PID) controller with ambient-load feedforward, back-calculation anti-windup, hot-side derating and a dew-point safety limiter. Three scenarios—hybrid (H), active (A) and passive (P)—were evaluated over 10,173 one-second intervals (10,174 records; 2.8258 h) while the prescribed ambient temperature rose from 16 to 32 °C, and ambient relative humidity fell from 67% to 27%. H and A remained within the broader 16–20 °C preservation band for 100% of the run and within the tighter 17.5–18.5 °C control band for 79.7% and 80.5%, respectively, finishing at 18.53 °C and 18.56 °C. P reached 21.20 °C and remained within the tighter band for 47.7% of the run. Calculated electrical consumption was 0.05177 kWh for H, 0.05156 kWh for A and 0.00565 kWh for P. Relative humidity remained within 45–55% in all scenarios. The filtered H and A scenarios reduced mean PM2.5 and total volatile organic compound (TVOC) exposure by 98.4% and 94.4%, respectively, relative to the prescribed ambient profiles. The graphs for document prototype construction and functional bench observations and model results that have not yet been validated by enclosure tests are presented in Results Section. The close H/A performance over this short disturbance does not establish an advantage of ArtSorb and requires repeated humidity-disturbance experiments.
The authors' abstract, as published at the source. Applied Sciences, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Conservation
ConservationArts and Humanities