Digital impressions for maxillary complete dentures showed high trueness (mean RMS deviation 234.63 ± 43.87 μm, significantly below 300 μm), but conventional impressions resulted in superior retention, stability, and support in clinical performance.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Digital impressions for complete dentures had a mean RMS deviation of 234.63 ± 43.87 μm, significantly better than the 300-µm reference threshold.
  • Trueness of digital impressions varied by region, with lower deviations in the palatal vault and ridge crest, but higher deviations in the peripheral border and posterior palatal seal.
  • Denture bases made from conventional impressions showed significantly superior posterior retention, lateral and anteroposterior stability, and anteroposterior support.
  • No significant differences were found in anterior retention or lateral support between the two impression methods.

AI-generated from the title and abstract; the full text is not read.

Abstract

This study aimed to compare the three-dimensional trueness of digital impressions with conventional impressions for maxillary complete dentures and to evaluate the clinical performance of denture bases fabricated from each technique. Twenty completely edentulous participants received both conventional impressions and digital impressions using an intraoral scanner in a randomized crossover design. Conventional impressions were digitized and used as reference models. Trueness was assessed by root mean square (RMS) deviations for the entire surface and predefined anatomical regions. Denture bases were fabricated using stereolithographic 3D printing. Retention, stability, and support were clinically evaluated by blinded examiners. Statistical analyses included parametric and nonparametric tests (α = 0.05) with effect size estimation. Mean RMS deviation for the entire digital impression was 234.63 ± 43.87 μm and was significantly below the 300-µm reference threshold (Cohen’s d = − 1.49, representing the standardized difference from this threshold). The palatal vault (d = − 3.03) and ridge crest (d = − 2.88) showed the largest standardized differences below the 300-µm threshold, whereas the peripheral border (d = 1.47) and posterior palatal seal (d = 0.85) showed standardized differences above the threshold ( P ≤ 0.001). Conventional denture bases showed significantly higher posterior retention, lateral and anteroposterior stability, and anteroposterior support ( r = 0.60–0.77; P ≤ 0.007). No significant differences were observed for anterior retention or lateral support. Digital impressions demonstrated region-dependent trueness relative to conventional reference impressions, with lower deviations in the palatal vault and ridge crest regions and greater deviations in peripheral and posterior sealing regions. However, conventional impressions provided superior clinical performance for several retention, stability, and support parameters.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Orthodontics

OrthodonticsDentistry