PofoliaShared via Pofolia

Journal of Magnetic Resonance Imaging· 2026Q1

A Survey and Analysis of the Current Status of MRI Safety Management in Medical Institutions in Korea

Chung-Hwan Kang, Kyoo‐Jin Yeon, Yu‐jin Shin, Kyung-Bae Lee

Short summary

A 2025 survey of all 47 Korean tertiary hospitals revealed a composite MRI safety maturity score of 63.08/100, with critical areas like ferromagnetic detection systems and MRSO appointments showing only 17.0% compliance.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The average MRI safety maturity score across 47 Korean tertiary hospitals was 63.08 out of 100.
  • Compliance was low for ferromagnetic detection systems (17.0%) and MRSO appointment (17.0%).
  • Level 1 safety education compliance was only 23.4%.
  • Two-person staffing for MRI procedures decreased from 97.9% during weekday daytime to 38.3% on holidays.
  • 44.7% of hospitals reported MRI-related safety incidents.

AI-generated from the title and abstract; the full text is not read.

Abstract

BACKGROUND: MRI safety management is essential for patient safety and for standardizing institutional practices. However, nationwide data on MRI safety readiness in Korean tertiary hospitals remain limited. PURPOSE: To evaluate MRI safety management across all 47 Korean tertiary hospitals and identify major gaps in safety infrastructure, staffing, and education. STUDY TYPE: Cross-sectional census survey. POPULATION: MRI safety managers from all 47 Korean tertiary hospitals in 2025. ASSESSMENT: A structured 50-item questionnaire was developed based on the American College of Radiology (ACR) MRI safety guidelines. A composite safety maturity index (0-100) was calculated as the unweighted arithmetic mean of four domain scores derived from 32 binary safety-practice items, with mandatory items weighted 2 and recommended items weighted 1 in accordance with the 2024 ACR Manual on MR Safety. STATISTICAL TESTS: Descriptive statistics were used to summarize institutional characteristics and safety compliance. Comparisons of staffing patterns by time period were evaluated using inferential tests, with statistical significance set at p < 0.05. RESULTS: The response rate was 100% (47/47). The mean number of MRI units per hospital was 5.32 ± 3.50, and 3.0 T systems were predominant. Compliance was universal for closed-circuit television (CCTV) monitoring and MR Conditional monitoring devices but was low for ferromagnetic detection systems (17.0%), Magnetic Resonance Safety Officer (MRSO) appointment (17.0%), and Level 1 safety education (23.4%). MRI-related safety incidents were reported by 44.7% of hospitals. Two-person staffing decreased significantly from 97.9% on weekday daytime hours to 55.3% on Saturdays, 44.7% at night, and 38.3% on holidays. The overall composite safety maturity score was 63.08 ± 15.04. DATA CONCLUSION: Considerable variability remains in MRI safety management across Korean tertiary hospitals. These findings highlight the need for national MRI safety standards in the Republic of Korea. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 4.

The authors' abstract, as published at the source. Journal of Magnetic Resonance Imaging, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Emergency Medical Services

Emergency Medical ServicesHealth Professions