PofoliaPofolia ile paylaşıldı

Journal of Endovascular Therapy· 2026Q1· Olgu sunumu

Akut Tıkanmış Vena Kava Filtresinin Geri Alınması ve İlişkili Kaval Tıkanıklığının FlowTriever ve ClotTriever Sistemleri Kullanılarak Mekanik Trombektomisi (Trombusun Embolik Koruma Olarak Kullanılmasıyla)

Retrieval of Thrombosed Inferior Vena Cava Filter and Mechanical Thrombectomy of Associated Caval Thrombosis Using FlowTriever and ClotTriever Systems With the ClotTriever as Embolic Protection

S So, Dexter Yak Seng Chan, SC Tam, Skyi Yin‐Chun Pang ve diğerleri

Kısa özet

Tıkanmış bir inferior vena kava filtresinin (IVCF) ve ilişkili kaval tıkanıklığının, ClotTriever'ın embolik koruma olarak kullanıldığı FlowTriever ve ClotTriever cihazları ile başarılı bir şekilde çıkarılmasını sağlayan yeni bir teknik sunulmuştur.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Anti-fosfolipid sendromu ve IVCF'ye bağlı kaval tıkanıklığı olan 55 yaşındaki bir hastada mekanik trombektomi ve filtre çıkarma işlemi yapıldı.
  • IVC ve iliofemoral venlerin endovenöz mekanik trombektomisi için FlowTriever cihazı kullanıldı.
  • Tıkanmış IVCF'nin çıkarılması sırasında ClotTriever cihazı alternatif bir embolik koruma stratejisi olarak kullanıldı.
  • İşlem başarılı oldu ve pulmoner emboli belirtisi görülmedi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

A 55-year-old Chinese male with anti-phospholipid syndrome presented with left lower limb deep venous thrombosis (DVT) on warfarin and had an inferior vena cava filter (IVCF) implanted before a radical resection of a perineal sarcoma. The inferior vena cava (IVC) filter removal was attempted 2 weeks after the surgery, but thrombus was found at the filter. It was decided to leave the filter and to continue with anticoagulation. He presented with progressive right lower limb swelling, erythema and pain, with a CT venogram showing caval thrombosis extending from the IVC filter to the right below-knee veins. In view of worsening symptoms, endovenous mechanical thrombectomy of the IVC and iliofemoral veins, as well as caval filter removal, was performed using the ClotTriever and FlowTriever devices (Inari Medical, US). The ClotTriever itself was then placed alongside a 16Fr internal jugular vein (IJV) sheath to remove the thrombosed filter. The FlowTriever disc was next deployed from jugular access as proximal embolic protection during the thrombectomy procedure. The procedure was successful with no symptoms of pulmonary embolism (PE). This report illustrates the alternative use of the ClotTriever BOLD as an intra-operative proximal embolic protection in the absence of alternative devices like a ProTrieve sheath, during caval thrombectomy and removal for caval thrombosis secondary to an IVC filter. Clinical Impact The ClotTriever BOLD catheter, deployed alongside a large retrograde sheath may be considered as an proximal embolic protection for removing thrombosed IVCFs, where there is patient with a suitably sized IVC and when alternative and appropriate devices are unavailable.

Yazarların özeti; kaynağından alınmıştır. Journal of Endovascular Therapy, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: İç Hastalıkları

Internal MedicineMedicine