PofoliaShared via Pofolia

Analytical Chemistry· 2026Q1

Instrument-Agnostic Machine Learning Framework for Accurate Prediction of Functional Groups from Tandem Mass Spectrometry

Connor H. Beveridge, Prageeth R. Wijewardhane, Matthew Muhoberac, Nicolás M. Morato et al.

Short summary

A new machine learning framework predicts functional groups directly from MS/MS spectra, achieving 87% F1 score on public data and 76% on custom data, and successfully transfers predictions between different mass spectrometry instruments without database searches.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Introduces an instrument-agnostic ML framework for predicting functional groups from MS/MS spectra.
  • Achieves average molecular F1 scores of 87% (MONA) and 76% (DESI), and accuracies of 94% (MONA) and 87% (DESI).
  • Demonstrates successful transfer of predictions from DESI-generated data to spectra from Orbitrap and TOF instruments in different labs.
  • Eliminates the need for conventional database searches in structural elucidation.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Structural elucidation of unknown compounds using tandem mass spectrometry (MS/MS) is an ongoing challenge. Expert chemists will often use common product ion peaks and neutral losses or peak matching software to predict structural aspects from MS/MS spectra, a process which is time consuming and limited by the molecular entries in the database. We introduce an instrument-agnostic machine learning (ML) framework that predicts functional groups directly from MS/MS spectra, eliminating the need for conventional database searches. The ML models are trained on data from different sources, the MassBank of North America (MONA), a public database, and a custom MS/MS database acquired using a single high throughput desorption electrospray ionization (DESI) MS/MS platform to showcase transferability of model predictions independent of instrument acquisition. Additionally, a novel spectral representation is developed for ML use by standardizing the spectra to the precursor ion m/z. We utilized molecular metrics, specifically, average molecular F1 score of 87% (MONA) and 76% (DESI) and average molecular accuracy of 94% (MONA) and 87% (DESI), indicating similar model performance when trained on different databases to validate the ML framework. To further illustrate the robustness and transferability of our ML framework, models trained on DESI-generated data successfully predicted functional groups, using spectral data generated from a blind test set of molecules using two different company laboratories using distinct mass spectrometry instruments (Orbitrap and TOF) operated in positive-ion mode electrospray ionization. We believe that such an approach, where models trained on data from one instrument can reliably make accurate predictions on spectra acquired using different instruments in a database-free manner, will significantly expand the practical applications of ML to mass spectrometry.

The authors' abstract, as published at the source. Analytical Chemistry, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Spectroscopy

SpectroscopyChemistry