PofoliaShared via Pofolia

Buildings· 2026Q1

Simulation and Optimization Research on Photovoltaic Power Generation in Rural Office Buildings in Hot Summer and Cold Winter Regions

Xingxing Chen, Jiahong Zhou, Ziqi Yao, Fang’ai Chi

Short summary

An optimized photovoltaic system for a rural office building in a hot summer/cold winter region achieved a 56% increase in annual power generation (to 13.7 × 10^4 kWh) and a 288.11% net energy saving rate, enabling complete energy self-sufficiency.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Optimal PV installation parameters identified as a 27° tilt angle and an 18° east-of-south azimuth.
  • Optimized system increased average annual power generation by 56% (from 8.9 × 10^4 kWh to 13.7 × 10^4 kWh) compared to the original design.
  • Optimized design achieved a net energy saving rate of 288.11%, significantly outperforming the original design's 179.76%.
  • The optimized building design achieved complete grid independence and a net energy surplus.

AI-generated from the title and abstract; the full text is not read.

Abstract

Against the backdrop of rural energy transitions and the large-scale implementation of Building-Integrated Photovoltaics (BIPV), the photovoltaic (PV) design for rural office buildings in hot summer and cold winter regions faces a conflict between maximizing power generation and minimizing net energy consumption, along with a lack of refined multi-objective optimization frameworks. Taking a typical rural double-sloped-roof office building in the Jianghan Plain as the research subject, this study establishes a multi-objective optimization framework that integrates parametric modeling and a multi-objective genetic algorithm to obtain a Pareto-optimal solution set. Three scenarios—no PV, the original design, and the optimized design—were simulated and compared. The results indicate that: (1) The optimal installation parameters are a 27° tilt angle and an 18° east-of-south azimuth. Compared to the original design, the optimized system increases the average annual power generation by 56% (from 8.9 × 104 kWh to 13.7 × 104 kWh). (2) The optimized design reduces the building’s net energy consumption to −9.86 × 104 kWh, achieving a comprehensive energy-saving rate of 288.11%, significantly outperforming the original design’s 179.76%. (3) This synergistic design enables the building to completely eliminate grid dependence, achieving energy self-sufficiency and a net energy surplus. This study provides a scientific reference for the refined BIPV design and low-carbon retrofitting of rural public buildings in similar climatic zones.

The authors' abstract, as published at the source. Buildings, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Renewable Energy, Sustainability and the Environment

Renewable Energy, Sustainability and the EnvironmentEnergy