Short summary
An optimized photovoltaic system for a rural office building in a hot summer/cold winter region achieved a 56% increase in annual power generation (to 13.7 × 10^4 kWh) and a 288.11% net energy saving rate, enabling complete energy self-sufficiency.
AI-generated from the title and abstract; the full text is not read.
Key points
- Optimal PV installation parameters identified as a 27° tilt angle and an 18° east-of-south azimuth.
- Optimized system increased average annual power generation by 56% (from 8.9 × 10^4 kWh to 13.7 × 10^4 kWh) compared to the original design.
- Optimized design achieved a net energy saving rate of 288.11%, significantly outperforming the original design's 179.76%.
- The optimized building design achieved complete grid independence and a net energy surplus.
AI-generated from the title and abstract; the full text is not read.
Abstract
Against the backdrop of rural energy transitions and the large-scale implementation of Building-Integrated Photovoltaics (BIPV), the photovoltaic (PV) design for rural office buildings in hot summer and cold winter regions faces a conflict between maximizing power generation and minimizing net energy consumption, along with a lack of refined multi-objective optimization frameworks. Taking a typical rural double-sloped-roof office building in the Jianghan Plain as the research subject, this study establishes a multi-objective optimization framework that integrates parametric modeling and a multi-objective genetic algorithm to obtain a Pareto-optimal solution set. Three scenarios—no PV, the original design, and the optimized design—were simulated and compared. The results indicate that: (1) The optimal installation parameters are a 27° tilt angle and an 18° east-of-south azimuth. Compared to the original design, the optimized system increases the average annual power generation by 56% (from 8.9 × 104 kWh to 13.7 × 104 kWh). (2) The optimized design reduces the building’s net energy consumption to −9.86 × 104 kWh, achieving a comprehensive energy-saving rate of 288.11%, significantly outperforming the original design’s 179.76%. (3) This synergistic design enables the building to completely eliminate grid dependence, achieving energy self-sufficiency and a net energy surplus. This study provides a scientific reference for the refined BIPV design and low-carbon retrofitting of rural public buildings in similar climatic zones.
The authors' abstract, as published at the source. Buildings, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Renewable Energy, Sustainability and the Environment
Renewable Energy, Sustainability and the EnvironmentEnergy