PofoliaShared via Pofolia

BMC Oral Health· 2026Q1

Primary stability of short implants compared with standard implants placed with a simulated closed sinus floor elevation technique: an in vitro study

Emrah Genceli, Hilal Ağar, Süleyman Çağatay Dayan, Serdar Çintan et al.

Short summary

Short implants showed comparable primary stability to standard implants placed with a simulated closed sinus floor elevation technique in an in vitro model (n=40).

AI-generated from the title and abstract; the full text is not read.

Key points

  • Primary stability of short implants was compared to standard implants with simulated closed sinus floor elevation.
  • Resonance frequency analysis and Periotest measurements were used on 40 implants.
  • No statistically significant difference in primary stability was observed between short and standard implants (p > 0.05).
  • The study was conducted using an in vitro experimental model.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Background Primary implant stability is a key determinant of successful osseointegration, particularly in the posterior maxilla, where bone quality is often compromised. Short implants have been proposed as an alternative to sinus floor elevation; however, data comparing their primary stability with that of standard implants placed using closed sinus floor elevation remain limited. This in vitro study aimed to compare the primary stability of short and standard implants. Materials and methods An in vitro experimental model was used to assess primary implant stability. Short implants and standard implants placed following simulated closed sinus floor elevation were evaluated using resonance frequency analysis and Periotest measurements ( n = 40). Implant stability values were obtained from frontal and lateral directions, with five readings averaged in each direction for every implant. Descriptive statistics were calculated, and group comparisons were performed. Pearson correlation analysis was used to evaluate relationships between measurement directions within each implant group and between assessment methods. Results No statistically significant differences in primary stability were observed between short implants and standard implants based on either resonance frequency analysis or Periotest measurements ( p > 0.05). Conclusions Within the limitations of this in vitro model, no statistically significant difference in primary stability was detected between short and standard implants under similar crestal bone engagement. As healing, secondary stability, and loading were not assessed, clinical studies are required to confirm these findings. Trial registration Not applicable.

The authors' abstract, as published at the source. BMC Oral Health, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Oral Surgery

Oral SurgeryDentistry