PofoliaShared via Pofolia

Journal of Analytical Science & Technology· 2026Q2

Self-calibrated deadtime correction using poisson-tail invariance in event-driven electron detectors

Joohyun Lee, Ji-Hwan Kwon, Sooheyong Lee

Short summary

A novel monitor-free, self-calibrated method corrects deadtime in event-driven electron detectors by using the invariance of Poisson-tail inter-arrival times, increasing peak count rate by 67% (from 78 kHz to 131 kHz).

AI-generated from the title and abstract; the full text is not read.

Key points

  • Introduces a monitor-free, self-calibrated deadtime correction method for event-driven electron detectors.
  • Method relies on the invariance of the long-time Poisson tail of inter-arrival time distributions to estimate incident arrival rate.
  • Demonstrated in high-flux transmission electron microscopy, correcting deadtime-limited beam profiles.
  • Achieved a 67% increase in corrected peak count rate (78 kHz to 131 kHz) compared to raw data.

AI-generated from the title and abstract; the full text is not read.

Abstract

High-flux electron counting with event-driven detectors is fundamentally limited by pixel-level deadtime, resulting in nonlinear count loss, variance suppression, and distortion of spatial intensity profiles. We introduce a monitor-free, self-calibrated deadtime correction method based on the invariance of the long-time Poisson tail of inter-arrival time distributions. Under stationary Poisson illumination, the long-time inter-arrival tail provides an internal statistical estimate of the incident arrival rate, independent of external flux measurements. The approach is demonstrated using high-flux transmission electron microscopy beam-profile measurements, where spatial Fano-factor analysis confirms operation in the deadtime-limited regime. By calibrating an effective extended-deadtime model with the tail-derived rate, the corrected peak count rate increases from approximately 78 kHz to 131 kHz, corresponding to a 67% increase relative to the raw peak. These results establish a self-referenced framework for deadtime correction and dynamic-range extension in event-driven electron detectors, subject to the validity of the stationary-arrival and tail-invariance assumptions.

The authors' abstract, as published at the source. Journal of Analytical Science & Technology, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Surfaces, Coatings and Films

Surfaces, Coatings and FilmsMaterials Science