Statik Bilgisayar Destekli İmplant Cerrahisi Doğruluğu Değerlendirildi

The accuracy of static computer‐aided implant surgery: A systematic review and meta‐analysis

Ali Tahmaseb, Vivian Wu, Daniël Wismeijer, Wim Coucke ve diğerleri

Kısa özet

Statik bilgisayar destekli implant cerrahisi (s-CAIS), 20 çalışmanın meta-analizine göre, giriş noktasında ortalama 1.2 mm ve apikalde 1.4 mm'lik yerleştirme hatası ve 3.5°'lik açısal sapma göstermektedir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Statik bilgisayar destekli implant cerrahisi için ortalama cerrahi hata payı 1.2 mm (giriş) ve 1.4 mm'dir (apeks).
  • İmplant yerleştirmede ortalama açısal sapma 3.5°'dir.
  • Doğruluk, tam dişsiz hastalara göre kısmen dişsiz hastalarda anlamlı derecede daha iyidir.
  • Teknik ve tasarım değişkenliği nedeniyle en az 2 mm'lik bir güvenlik marjı tavsiye edilir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

OBJECTIVES: To assess the literature on the accuracy of static computer-assisted implant surgery in implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about the accuracy of static computer-assisted implant systems. Meta-regression analysis was performed to summarise the accuracy studies. RESULTS: From a total of 372 articles. 20 studies, one randomised controlled trial (RCT), eight uncontrolled retrospective studies and 11 uncontrolled prospective studies were selected for inclusion for qualitative synthesis. A total of 2,238 implants in 471 patients that had been placed using static guides were available for review. The meta-analysis of the accuracy (20 clinical) revealed a total mean error of 1.2 mm (1.04 mm to 1.44 mm) at the entry point, 1.4 mm (1.28 mm to 1.58 mm) at the apical point and deviation of 3.5°(3.0° to 3.96°). There was a significant difference in accuracy in favour of partial edentulous comparing to full edentulous cases. CONCLUSION: Different levels of quantity and quality of evidence were available for static computer-aided implant surgery (s-CAIS). Based on the present systematic review and its limitations, it can be concluded that the accuracy of static computer-aided implant surgery is within the clinically acceptable range in the majority of clinical situations. However, a safety marge of at least 2 mm should be respected. A lack of homogeneity was found in techniques adopted between the different authors and the general study designs.

Yazarların özeti; kaynağından alınmıştır. Clinical Oral Implants Research, 2018 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Ağız Cerrahisi

Oral SurgeryDentistry