PofoliaShared via Pofolia

ACS Sensors· 2026Q1

A Lateral Flow-Based Whole Blood Sample Preparation for Surface Plasmon Resonance Sensing of Ferritin in Frequent Blood Donors

Caroline Dubois, Noémie Loranger, Jonathan Robidoux, David Geilfus et al.

Short summary

A portable point-of-care surface plasmon resonance (SPR) assay uses a lateral flow strip to prepare whole blood samples, enabling ferritin quantification in 30 minutes for iron deficiency anemia screening in blood donors.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Developed a portable POC SPR assay for whole blood ferritin quantification.
  • Utilizes a lateral flow strip for rapid sample preparation, yielding an eluate.
  • Detects ferritin concentrations in the ng/mL range within 30 minutes.
  • Successfully discriminated between deficient and normal ferritin levels in blood donor samples.
  • Measurements showed good agreement with centrifuged serum and ELISA results.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Measurements from whole blood remain challenging with plasmonic techniques, especially for point-of-care (POC) measurements where infrastructure is limited. To address this need, we developed a portable POC surface plasmon resonance (SPR) assay for rapid ferritin quantification from whole blood that uses a lateral flow-based sample preparation strip to collect an eluate from whole blood. The concept is shown with clinical samples for monitoring iron deficiency anemia (IDA), a prevalent global health concern considered with care by blood banks, for which rapid POC quantification has yet to be achieved. The SPR assay detected ferritin concentrations in the ng/mL range from whole blood in 30 min, sufficient to discriminate concentrations at the clinically relevant threshold for IDA. Measurements from eluted blood showed good agreement with centrifuged serum and enzyme-linked immunosorbent assay (ELISA) results, allowing clear classification between deficient and normal ferritin levels despite minor variability among clinical samples collected from blood donors. With its portability, short analysis time, and minimal sample preparation, this method demonstrates strong potential for on-site protein sensing, as exemplified for ferritin screening at blood drives with minimal and simple blood preparation, providing a pathway toward future development of point-of-care tools for improved assessment of donor iron status.

The authors' abstract, as published at the source. ACS Sensors, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Biomedical Engineering

Biomedical EngineeringEngineering