AIAA Journal· 2026Q1
Fast-Responding Cryogenic Pressure-Sensitive Paint with Porous PTMSP-Based Binder
- 0citations
- Q1SCImago
- 2026year
Short summary
A new cryogenic pressure-sensitive paint (cryoPSP) using a porous PTMSP binder with treated silica nanoparticles achieves a model-estimated cutoff frequency of 2833 Hz at 150 K and 100 Pa, significantly faster than conventional cryoPSP.
AI-generated from the title and abstract; the full text is not read.
Key points
- Developed a fast-responding cryoPSP using a porous PTMSP binder and hydrophobically treated colloidal silica nanoparticles.
- The PTMSP binder with silica nanoparticles forms a porous coating with improved adhesion, even at high particle loadings.
- Model-estimated cutoff frequency reached 2833 Hz at 150 K and 100 Pa for a formulation with 95 wt% silica.
- The paint maintained stable pressure and temperature sensitivities for over 100 hours.
AI-generated from the title and abstract; the full text is not read.
Abstract
Fast-responding pressure-sensitive paint (PSP) is required for measuring unsteady surface pressure in cryogenic wind tunnels. However, the temporal response of conventional cryogenic PSP (cryoPSP) is limited by oxygen diffusion in the polymer binder. This study presents a fast-responding cryoPSP based on a porous poly[1-(trimethylsilyl)-1-propyne] (PTMSP) binder containing hydrophobically treated colloidal silica nanoparticles. The affinity between the trimethylsilyl-modified silica particles and PTMSP enables the formation of a porous coating with improved adhesion to model surfaces, even at high particle loadings. The response under cryogenic conditions was estimated using a model that accounts for oxygen diffusion in the binder and the luminescence lifetime of Pt(II) meso-tetra(pentafluorophenyl)porphine. For a formulation containing 400 nm colloidal silica particles at 95 wt%, the model-estimated cutoff frequency was 2833 Hz at 150 K and an oxygen partial pressure of 100 Pa. A sensitivity analysis showed that the cutoff frequency remained above 1 kHz even when the diffusion time constant was increased by a factor of 2.8. Pressure and temperature sensitivities remained stable for up to 119 h after coating. These results suggest that the proposed porous cryoPSP extends the measurable frequency range for unsteady pressure measurements in cryogenic wind tunnels, although direct response-time validation under cryogenic conditions remains necessary.
The authors' abstract, as published at the source. AIAA Journal, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
BioengineeringChemical Engineering