PofoliaShared via Pofolia

Magnetic Resonance Materials in Physics Biology and Medicine· 2026Q2

T2 mapping of individual fascicles of the sciatic nerve at 7 T using multi-echo spin–echo

Emilie Sleight, Gian Franco Piredda, Frédéric Grouiller, Ludovica Romanin et al.

Short summary

High-resolution 7 T MRI with accelerated multi-echo spin-echo sequences can map T2 values of individual sciatic nerve fascicles (0.4x0.4x3.0 mm3 resolution), revealing lower T2 in fascicles (57.0 ms) than surrounding tissues.

AI-generated from the title and abstract; the full text is not read.

Key points

  • 7 T MRI achieved 0.4x0.4x3.0 mm3 resolution, visualizing individual sciatic nerve fascicles.
  • T2 values were lower in fascicles (57.0 ms) than in the intraneural compartment (76.2 ms) and intermuscular fat (132.7 ms).
  • GRAPPATINI acceleration reduced acquisition time from 11:05 to 3:35 min without compromising T2 consistency.
  • Overlaying T2 maps on S0 maps improved fascicle delineation and anatomical interpretation.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Objective Neuropathies can selectively affect individual fascicles within peripheral nerves, but diagnosis is limited by MRI spatial resolution and signal-to-noise ratio. This feasibility study aimed to leverage 7 T MRI to measure sub-millimetric T 2 maps of sciatic nerve fascicles in healthy subjects. Materials and methods Accelerated multi-echo spin–echo sequences were acquired in six healthy volunteers at 7 T. Acceleration included generalised autocalibrating partially parallel acquisition (GRAPPA) and GRAPPATINI, which integrates GRAPPA with model-based accelerated relaxometry. Extended phase graph (EPG) modelling of signal decay was used to compute T 2 maps. Quantitative maps were visually assessed and T 2 values were extracted from regions of interest. Results High-resolution imaging (0.4×0.4x3.0 mm 3 ) enabled visualisation of individual fascicles. T 2 values were lower in fascicles (57.0 ms) than in the non-fascicular intraneural compartment (76.2 ms) and intermuscular fat (132.7 ms). Compared with GRAPPA alone, GRAPPATINI reduced acquisition time (11:05 to 3:35 min) while maintaining fascicle depiction and T 2 consistency (mean difference: 1.45 ms). Overlaying T 2 on S 0 maps enhanced fascicle delineation, facilitating anatomical interpretation. Discussion This approach demonstrated the feasibility of high-resolution T 2 mapping of peripheral nerve fascicles at 7 T, offering a potential tool for improved assessment of nerve microstructure and early neuropathy detection.

The authors' abstract, as published at the source. Magnetic Resonance Materials in Physics Biology and Medicine, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Radiology, Nuclear Medicine and Imaging

Radiology, Nuclear Medicine and ImagingMedicine