PLoS ONE· 2026Q1
Heart rate and blood pressure variability, and baroreflex sensitivity, during heat exposure in persons with type 2 diabetes and hypertension
- 0citations
- Q1SCImago
- 2026year
Short summary
Individuals with type 2 diabetes (T2D) and hypertension show blunted autonomic responses to heat exposure, with smaller increases in heart rate and reduced changes in heart rate variability and baroreflex sensitivity compared to healthy controls.
AI-generated from the title and abstract; the full text is not read.
Key points
- Heat exposure increased heart rate less in T2D individuals (5.43 bpm) than in controls (13.96 bpm) (p=0.014).
- Reductions in heart rate variability (HRV) indices like HF RR were smaller in T2D individuals (54.5% reduction) compared to controls (74% reduction) (p=0.038).
- Baroreflex sensitivity (BRS) measures, including LF BRS, HF BRS, and mean BRS, decreased significantly less in T2D individuals (25-26% reduction) than in controls (51-58% reduction) (p=0.010-0.034).
- Combined T2D and hypertension appear to blunt autonomic responses to short-term heat exposure.
AI-generated from the title and abstract; the full text is not read.
Abstract
The autonomic nervous system regulates cardiovascular homeostasis during stressors such as heat, but the effects of type 2 diabetes (T2D) with hypertension on such responses are unclear. Twenty male participants (10 with type 2 diabetes and hypertension and 10 age-matched healthy controls; mean ages 64 ± 4.14 and 63 ± 5.42 years) underwent a 90-minute whole-body heat exposure at 40 °C and 50% relative humidity. Heart rate variability (HRV), baroreflex sensitivity (BRS), and blood pressure variability (BPV) were assessed before, during and after the heat exposure. Heat exposure increased heart rate in both groups but this response was less in T2D (5.43 bpm; ~ 7% increase) versus controls (13.96 bpm; ~ 22% increase; p = 0.014). Similarly, reductions in HRV indices to heat stress were generally smaller in magnitude among participants with T2D. For example, high-frequency power (HF RR) decreased by 31.21 ms² (~54.5% reduction) in T2D because of heat exposure, compared with a reduction of 179.35 ms² (~74% reduction) in controls (p = 0.038). Further, LF BRS decreased by 1.07 ms/mmHg (~25% reduction) vs. 3.96 ms/mmHg (~51% reduction) (p = 0.021), HF BRS by 1.58 ms/mmHg (~35% reduction) vs. 4.15 ms/mmHg (~62% reduction) (p = 0.034), and mean BRS by 1.18 ms/mmHg (~26% reduction) vs. 4.16 ms/mmHg (~58% reduction) (p = 0.010) in those with T2D versus controls, respectively. Low-frequency power (LF RR), LF/HF ratio and BPV parameters also showed smaller (though nonsignificant) changes in T2D. Overall, combined T2D and hypertension produced blunted autonomic responses to short-term heat exposure, potentially increasing vulnerability to temperature extremes.
The authors' abstract, as published at the source. PLoS ONE, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Cardiology and Cardiovascular Medicine
Cardiology and Cardiovascular MedicineMedicine