PofoliaShared via Pofolia

Renal Failure· 2026Q1

Cross-elbow stent placement for refractory arteriovenous fistula stenosis and chronic total occlusion in hemodialysis patients: a single-center retrospective cohort of 42 cases

Yibiao Huang, Linnan Bai, Junnan Wu, Xuan Zheng et al.

Short summary

Cross-elbow stenting successfully treated refractory arteriovenous fistula stenosis and chronic total occlusions in 42 hemodialysis patients, achieving 100% technical and clinical success with no device-related complications.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Cross-elbow stenting was performed in 42 hemodialysis patients with refractory AVF stenosis or CTO.
  • Technical and clinical success rates were both 100%.
  • Mean access flow increased from 407 ± 267 to 839 ± 188 mL/min.
  • Target lesion primary patency was 76.9% at 12 and 24 months.
  • No stent fracture, migration, kinking, or infection complications were observed.

AI-generated from the title and abstract; the full text is not read.

Abstract

Cross-elbow stent placement in hemodialysis arteriovenous fistulas (AVFs) has been avoided due to risks of fracture, kinking, deformation, migration, and infection. However, elbow lesions may be refractory to angioplasty and progress to chronic total occlusion (CTO). We evaluated the safety, feasibility, and patency of cross-elbow stenting for AVF salvage. Consecutive adult hemodialysis patients who received cross-elbow stents for clinically significant AVF stenosis or CTO (September 2021 - March 2026) at a single center were retrospectively analyzed. Primary outcomes were target lesion primary patency (TLPP), access circuit primary patency (ACPP), access circuit secondary patency, and access circuit assisted primary patency, estimated by Kaplan-Meier. Technical and clinical success and complications were recorded. Forty-two patients were included; 45.2% had CTO and 57.1% had prior PTA. Eluvia-based stents were used in 83.3%. Technical and clinical success were both 100%. Mean access flow increased from 407 ± 267 to 839 ± 188 mL/min. TLPP at 3, 6, 12, and 24 months was 90.1%, 84.4%, 76.9%, and 76.9%, respectively. No stent fracture, migration, kinking, or infection occurred. Cross-elbow stenting was technically feasible and provided favorable short- to mid-term patency without device-related complications, supporting its use as a salvage option for selected refractory AVF lesions and CTOs.

The authors' abstract, as published at the source. Renal Failure, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Emergency Medical Services

Emergency Medical ServicesHealth Professions