Analytical Chemistry· 2026Q1
Charge Loss of Proteins in vacuo: Implications for Native Mass Spectrometry and Ion Mobility
- 1citations
- Q1SCImago
- 2026year
Short summary
Protein ions lose charge within native IM-MS instruments due to gas-phase collisions, altering charge state distributions and ion mobility data.
AI-generated from the title and abstract; the full text is not read.
Key points
- Protein ions lose charge within native IM-MS instruments via gas-phase collisions.
- Charge loss was observed on two instrument platforms, both polarities, and for three different proteins.
- Collision gas pressure significantly impacts charge loss magnitude, with higher charge states affected more.
- Dissociation of salt adducts drives charge loss, which can be reduced by desalting samples.
- Quadrupole selection may influence collision-induced unfolding fingerprints, potentially related to charge loss.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Native ion mobility−mass spectrometry (IM−MS) is a powerful biophysical technique for characterizing protein structure. Because individual charge states often exhibit distinct structural dynamics, accurate IM-MS measurements require charge states to be examined independently. Although anecdotal reports among mass spectrometrists suggest that protein ions can lose charges during native IM-MS experiments, a thorough investigation of this phenomenon has been lacking. Here, we demonstrate that protein ions undergo charge loss inside the mass spectrometer as a direct consequence of gas-phase collisions, potentially leading to altered charge state distributions and ion mobility data. This effect was consistently observed across two instrument platforms (Synapt G2-S and Q Exactive UHMR), both ion polarities (positive and negative mode) and for three proteins (bovine serum albumin, myoglobin, and immunoglobulin G). Systematic investigations of instrumental parameters revealed that collision gas pressure has the strongest impact on the magnitude of charge loss, and that higher charge states are more affected than lower charge states. We further show that this process is largely driven by the dissociation of salt adducts and can hence be minimized through desalting in solution or inside the mass spectrometer, prior to the first m/z-analyzer (usually a quadrupole). For collision-induced unfolding experiments, significant differences were found between fingerprints acquired with and without quadrupole selection, although it remains unclear whether this phenomenon is directly related to charge loss. Overall, our study provides fundamental insights into collision-induced charge loss as a source of error in native IM-MS measurements and discusses the relevance of quadrupole m/z-selection for improving confidence in IM studies.
The authors' abstract, as published at the source. Analytical Chemistry, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Spectroscopy
SpectroscopyChemistry