PofoliaShared via Pofolia

BMC Nutrition· 2026Q2

Influence of enteral nutrition viscosity on international dysphagia diet standardisation initiative classification, feeding tube, and pump infusion compatibility

Raquel Cavalcante de Vasconcelos, Juliana Nunes Ferreira Correia de Vasconcelos, Gustavo Cavalcante de Vasconcelos, Paulo Roberto Cavalcante de Vasconcelos et al.

Short summary

Increasing caloric density of a fiber-free enteral formula significantly raises viscosity (27.50 to 347.83 cP) and IDDSI classification (0 to 3), while reducing gravity flow rates through feeding tubes (12.5 to 2.5 mL/min).

AI-generated from the title and abstract; the full text is not read.

Key points

  • Mean viscosity of a fiber-free enteral formula increased from 27.50 ± 1.03 to 347.83 ± 6.21 cP as caloric density rose from 1.0 to 2.5 kcal/mL.
  • IDDSI classification ranged from level 0 to 3 with increasing caloric density.
  • Gravity flow rates through a 12 Fr feeding tube decreased from 12.5 mL/min at 1.5 kcal/mL to 2.5 mL/min at 2.3 kcal/mL.
  • Pump infusion showed greater dispersion at higher densities (1.8–1.9 kcal/mL), with unsuccessful passage reported qualitatively at ≥ 2.0 kcal/mL.

AI-generated from the title and abstract; the full text is not read.

Abstract

Viscosity is an important physical property of enteral nutrition because it can affect administration through feeding tubes and infusion systems. This study evaluated viscosity, International Dysphagia Diet Standardisation Initiative (IDDSI) classification, and device performance across increasing caloric densities of a powdered enteral formula. A fiber-free powdered formula was prepared at 16 caloric densities (1.0–2.5 kcal/mL) at 25 °C. Viscosity was measured in six replicates per condition, and thickness was classified using the IDDSI syringe flow test. Gravity administration through 4–16 French (Fr) feeding tubes and pump infusion programmed at 100 mL/h were assessed. Viscosity was compared using one-way analysis of variance with Tukey’s post hoc test; Spearman correlation described the ordered concentration–viscosity relationship. Mean viscosity increased from 27.50 ± 1.03 to 347.83 ± 6.21 cP ( P < 0.0001), with IDDSI levels ranging from 0 to 3. Single documented 12 Fr collections at 1.5, 1.8, and 2.3 kcal/mL yielded approximately 125, 75, and 25 mL over 10 min, corresponding to average flow rates of 12.5, 7.5, and 2.5 mL/min. Approximate residual syringe volumes were recoverable for four concentrations, without replicate residual measurements. Pump mass differences were available for 1.0–1.9 kcal/mL (six observations per condition), with greater dispersion at 1.8–1.9 kcal/mL. Unsuccessful passage was reported qualitatively at ≥ 2.0 kcal/mL, without a quantitative mass series. Increasing caloric density was associated with higher viscosity and IDDSI level and with reduced gravity flow in the tested formula. The combined measurements identify changes relevant to enteral administration, while supporting formula- and device-specific assessment rather than a universal compatibility threshold.

The authors' abstract, as published at the source. BMC Nutrition, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Speech and Hearing

Speech and HearingHealth Professions