PofoliaShared via Pofolia

Advanced Functional Materials· 2026Q1

Photomultiplication‐Type Broadband Organic Photodetectors With an ON/OFF Current Ratio Exceeding 79 000 Enabled by Self‐Assembled Ultra‐Thin Layer

Zixin Chai, Xingchao Zhao, Lu Zhang, Xiaojuan Dai et al.

Short summary

New organic photodetectors (PM-BOPDs) achieve an ON/OFF current ratio exceeding 79,000 by using a P3HT:BTPSe-Ph4F (100:2 w/w) active layer and a 3-BPIC-F self-assembled layer, enabling high sensitivity for weak-light detection.

AI-generated from the title and abstract; the full text is not read.

Key points

  • PM-BOPDs fabricated with P3HT:BTPSe-Ph4F (100:2 w/w) active layer and 3-BPIC-F self-assembled layer.
  • Achieved an ON/OFF current ratio of 79,020 and external quantum efficiency of 2970% at 625 nm.
  • Demonstrated high specific detectivity (1.16 × 10^13 Jones) indicating strong weak-light sensitivity.
  • Successfully applied in photoplethysmography (PPG) monitoring to extract heart rate information.

AI-generated from the title and abstract; the full text is not read.

Abstract

ABSTRACT Photomultiplication type broadband organic photodetectors (PM‐BOPDs) were fabricated by employing one wide bandgap polymer P3HT and one narrow bandgap non‐fullerene acceptor BTPSe‐Ph4F with a weight ratio of 100:2 as active layers. Plenty of isolated electron traps will be formed in the active layers due to the rather low BTPSe‐Ph4F content, leading to poor electron transport channels and efficient hole transport channels in the P3HT:BTPSe‐Ph4F (100:2, w/w) active layers. Photogenerated electrons will be trapped in the isolated BTPSe‐Ph4F; the trapped electrons near the Al electrode will induce interfacial band bending for hole tunneling injection from the external circuit. The dark current density of PM‐BOPDs can be further suppressed by ∼2 orders of magnitude by employing a 3‐BPIC‐F self‐assembled ultra‐thin layer to replace PEDOT:PSS. The optimal PM‐BOPDs display an external quantum efficiency of 2970%, an on/off current ratio of 79 020, and specific detectivity of 1.16 × 10 13 Jones at a frequency of 90 Hz at 625 nm light under −10 V bias, indicating strong weak‐light sensitivity of PM‐BOPDs. The optimized PM‐BOPD was employed for photoplethysmography (PPG) monitoring. PPG signals were successfully recorded during rest and exercise, and their characteristics were analyzed to extract heart rate information and identify characteristic pulse wave features.

The authors' abstract, as published at the source. Advanced Functional Materials, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Electrical and Electronic Engineering

Electrical and Electronic EngineeringEngineering