PofoliaShared via Pofolia

Physics in Medicine and Biology· 2026Q2

Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism

Amir Jabbarpour, Eric Jr Moulton, Sanaz I. Kaviani, Siraj Ghassel et al.

Short summary

A Bottleneck Transformer U-Net (BTU-Net) AI model matched human reader performance in identifying vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism diagnosis, achieving 0.529 sensitivity at 1.5 false positives per projection.

AI-generated from the title and abstract; the full text is not read.

Key points

  • A Bottleneck Transformer U-Net (BTU-Net) AI model was developed for automated segmentation of vascular perfusion defects in V/Q scans.
  • BTU-Net achieved human-level performance, with a sensitivity of 0.529 ± 0.026 at 1.5 false positives per projection rate, outperforming other AI models.
  • The model also showed a low false positive rate of 0.08 ± 0.01 on a set of low-likelihood patients.
  • The AI model was trained on 1,313 patients and validated on 329 patients, with performance evaluated on a hold-out set of 46 high-probability patients.

AI-generated from the title and abstract; the full text is not read.

Abstract

OBJECTIVE: Accurate interpretation of planar ventilation-perfusion (V/Q) scintigraphy, used for diagnosing pulmonary embolism (PE) based on PIOPED/EANM guidelines, requires objective assessment of mismatched V/Q defects. Manual delineation of V/Q defects is time-consuming, subject to interobserver variability, and rarely performed in practice, limiting standardized reporting and quantification of disease burden. To address these challenges, we evaluated four modern AI models for automated segmentation of vascular perfusion defects in planar V/Q scans and compared their performance to human annotators. APPROACH: We retrospectively identified 2,118 patients who underwent planar V/Q scans at The Ottawa Hospital (June 2019-February 2023). Six standard projections (ANT, POST, LAO, RAO, LPO, RPO) were included. Four 2D neural networks (U-Net, nnU-Net, Swin UNETR, and a Bottleneck Transformer U-Net [BTU-Net]) were trained on 1,313 patients (7,878 projections) and validated on 329 (1,974 projections) using physician-annotated defects. A hold-out test set of 46 high probability patients was used to evaluate segmentation quality, and defect detection accuracy using free-response receiver operating characteristic (FROC) analysis. MAIN RESULTS: BTU-Net was the only model performing on par with human readers, showing robust sensitivity across the entire range of segmentation probabilities. At 1.5 false positives per projection rate (FPPR), BTU-Net outperformed other models with sensitivity of 0.529 ± 0.026, On a separate hold-out set of low likelihood of disease patients (n=430), the lowest FPPR was 0.08 ± 0.01 for BTU-Net (P<0.0001). SIGNIFICANCE: BTU-Net enables rapid, consistent, and accurate interpretation of planar V/Q scans. Such tools may enhance diagnostic efficiency, standardize reporting, and support non-expert readers in evaluating PE.

The authors' abstract, as published at the source. Physics in Medicine and Biology, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Computer Vision and Pattern Recognition

Computer Vision and Pattern RecognitionComputer Science