Hydrogen Permeation Behavior of Uncoated and Copper-Coated DC01 Sheets Under Static Biaxial Stress

Kilian Stengel, Klaas Kunze, Holger Claus Hoche, Matthias Oechsner

Short summary

Elastic biaxial stress significantly reduces the barrier effectiveness of 5 µm electroplated copper coatings on DC01 steel, lowering permeation by a factor of 230, while slightly increasing substrate permeation by ~5%.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Biaxial stress slightly increased hydrogen permeation flux (~5%) and decreased diffusion in uncoated DC01 steel.
  • Copper-coated DC01 steel showed a permeation reduction factor of 230 under elastic biaxial stress.
  • Elastic biaxial stress significantly reduces the barrier effectiveness of electroplated copper coatings.

AI-generated from the title and abstract; the full text is not read.

Abstract

In pressurized hydrogen vessels, barrier coatings on steel are exposed to hydrogen and biaxial tensile stress simultaneously. This study investigates the hydrogen permeation behavior of uncoated and electroplated copper-coated DC01 sheets under static elastic biaxial tension with the hoop-to-axial stress ratio of a 700 bar Type I pressure vessel. Electrochemical permeation measurements according to ISO 17081 were performed on 0.2 mm thick DC01 specimens using a Devanathan–Stachurski cell. A cross-tension specimen and a dedicated loading device superimposed the biaxial stress during permeation testing. For uncoated specimens, biaxial stress tended to decrease the mean effective diffusion coefficient by 34% and to increase the steady-state permeation flux by about 5%, although not statistically significant for three specimens per condition. A repeated measurement after unloading indicated reversibility. In the unstressed state, no permeation transient was detected through a 5 µm electroplated copper layer. Under biaxial tensile stress, however, the copper-coated specimens showed a measurable permeation signal, with a permeation reduction factor of 230 and an apparent coating diffusion coefficient of 4.94 × 10−14 m2 s−1. The results show that elastic biaxial stress markedly reduces the barrier effectiveness of the electroplated copper coating, whereas its effect on substrate permeation is small.

The authors' abstract, as published at the source. Hydrogen, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Metals and Alloys

Metals and AlloysMaterials Science