PofoliaShared via Pofolia

Journal of Zoo and Wildlife Medicine· 2026Q2

Precision of the Advia 2120 for the complete blood count of African elephants (Loxodonta africana)

Samantha J. Cohen, Francisco O. Conrado, Joyce S. Knoll, Marjorie Bercier

Short summary

The Advia 2120 automated hematology analyzer demonstrates excellent precision for most complete blood count (CBC) parameters in African elephants (Loxodonta africana), with coefficients of variation (CVs) >10% only for low-count cell types like reticulocytes, eosinophils, and basophils.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Advia 2120 shows excellent precision for most CBC parameters in African elephants.
  • CVs >10% were observed for absolute reticulocyte, eosinophil, and basophil counts.
  • This is expected due to the low numbers of these cell types in peripheral blood.
  • Manual methods for elephant leukocyte differential counts are prone to error and time-consuming.

AI-generated from the title and abstract; the full text is not read.

Abstract

Elephant leukocytes exhibit distinctive morphologic features, including unique heterophils and monocytes, which pose a particular challenge for automated CBC analysis. Therefore, most automated analyzers cannot correctly identify elephant leukocytes. Many zoologic institutions have turned to manual methods for elephant leukocyte differential count, but these methods are prone to error and are time-consuming. The Advia 2120, a flow cytometry automated hematology analyzer, has the advantage of offering preprogrammed species-specific cell-gating parameters that should allow for correct cell differentiation. This study aimed to evaluate the precision (within run and between run) of the Advia 2120 for use in captive African elephants (Loxodonta africana). Whole blood samples were collected in K2 EDTA from three healthy adult female African elephants. Repeatability and reproducibility were excellent for most variables. Coefficients of variation were >10% for absolute reticulocyte counts, eosinophil counts, and basophil counts, which is expected with cell types that appear in low numbers in peripheral blood. Future studies investigating the accuracy of the Advia 2120 in elephants are necessary.

The authors' abstract, as published at the source. Journal of Zoo and Wildlife Medicine, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Medical Laboratory TechnologyHealth Professions