Healthcare· 2026Q1
Peripheral Vascular and Physiological Responses Associated with Electroacupuncture in Chronic Nonspecific Low Back Pain: A Randomized Controlled Trial
- 0citations
- Q1SCImago
- 2026year
Short summary
Electroacupuncture (EA) significantly reduced pain intensity (p < 0.003) and increased minimal clinically important difference (MCID) responder rates (RR = 6.00 at follow-up) compared to sham EA in patients with chronic nonspecific low back pain (CNLBP).
AI-generated from the title and abstract; the full text is not read.
Key points
- EA significantly reduced pain intensity (NRS) in CNLBP patients compared to sham EA (p < 0.003, r = 0.70–0.84).
- MCID responder rates were significantly higher in the EA group (RR = 3.75 after 6 sessions, RR = 6.00 at follow-up).
- EA increased local blood flow at the Shenshu (BL23) acupoint.
- Increased blood flow at acupoints correlated with pain improvement.
AI-generated from the title and abstract; the full text is not read.
Abstract
Objective: This exploratory study aimed to evaluate the effects of electroacupuncture (EA) on pain and functional outcomes in patients with chronic nonspecific low back pain (CNLBP), and to investigate objective peripheral physiological responses associated with clinical improvement. Methods: In this prospective, double-blind, randomized sham-controlled trial, adults with CNLBP received EA at Shenshu (BL23) and an ipsilateral Ashi acupoint three times weekly for 2 weeks, followed by a 4-week follow-up. The primary outcome was pain intensity assessed by the Numeric Rating Scale (NRS), with responder analysis based on the minimal clinically important difference (MCID; ΔNRS ≥ 2). Secondary outcomes included the Oswestry Disability Index (ODI), local microcirculatory perfusion, skin temperature, and muscle tissue properties. Results: Compared with sham EA, EA significantly reduced pain intensity after the first session, after six sessions, and at follow-up (p < 0.003; r = 0.70–0.84). MCID responder rates were significantly higher in the EA group after the first session, six sessions and at follow-up (p < 0.003; RR = 3.75 and 6.00 after six sessions and follow-up, respectively). EA increased local blood flow at BL23 after the first and sixth sessions. Skin temperature showed only a transient within-group increase, without a significant adjusted between-group difference. Similar trends were observed at Ashi acupoint, and increased blood flow was associated with pain improvement. Conclusions: EA improved pain and functional outcomes in patients with CNLBP while inducing measurable peripheral vascular and physiological responses. Increased local blood flow may represent a candidate physiological correlate of EA-related symptom improvement. These findings support the exploration of objective physiological markers in acupuncture research.
The authors' abstract, as published at the source. Healthcare, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Complementary and alternative medicine
Complementary and alternative medicineMedicine