Analytical Chemistry· 2026Q1
Metabolomic and Microbial Profiling of Rat Internal Organs for Postmortem Interval Estimation: A Multi-Omics Analysis
- 0citations
- Q1SCImago
- 2026year
Short summary
Metabolomic profiling of rat internal organs accurately estimated postmortem interval (PMI) within a 2-7 day window (RMSE 0.467-0.677 days), while microbial profiling yielded substantially higher errors.
AI-generated from the title and abstract; the full text is not read.
Key points
- Metabolomic profiles of rat internal organs closely tracked postmortem interval (PMI) within a 2-7 day window, with RMSEs ranging from 0.467 to 0.677 days.
- Microbial profiling of internal organs yielded substantially higher RMSEs than metabolomics alone, with point estimates still below the intercept-only baseline (approx. 2.0 days).
- 16S rRNA gene amplification for microbial analysis failed in most samples within the first 24 hours postmortem, limiting analysis to a 2-7 day window.
- Multi-omics integration provided limited, tissue-dependent added value, with significant improvements only observed in the spleen after specific corrections.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Accurate postmortem interval (PMI) estimation remains a major challenge in forensic medicine. Here, we tested whether full-length 16S rRNA gene profiles of internal organs add predictive information to untargeted LC−MS/MS metabolomics for PMI estimation in rats. Metabolomics-only, microbiome-only, early-fusion, and stacking models were compared under leakage-controlled leave-one-animal-out (LOAO) validation, with parsimonious fixed-K models selecting the top 10 metabolites and top 5 microbial features within each training partition. 16S amplification failed in all 30 day-0 and 25 of 30 day-1 internal-organ samples, in both the full-length assay and an independent V3−V4 assay, indicating that the microbial signal of internal organs is effectively undetectable in the first 0−24 h; modelling therefore covered a 2−7 day window. Metabolomic profiles tracked PMI closely (LOAO RMSE 0.467−0.677 days across tissues), whereas microbiome-only models yielded substantially higher RMSEs than the metabolomics models, although their point estimates remained below the intercept-only baseline (RMSE approximately 2.0 days). The added value of multi-omics integration was limited and tissue dependent: stacking yielded a significantly lower RMSE than metabolomics alone only in the spleen after within-tissue correction, and this difference did not remain significant after correction across the full set of comparisons. All performance estimates are internal, derived from a single cohort without independent validation, and no forensic applicability is claimed; confirmation in independent animal cohorts, broader environmental conditions, and ultimately human forensic samples is required.
The authors' abstract, as published at the source. Analytical Chemistry, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Insect Science
Insect ScienceAgricultural and Biological Sciences