Scientific Reports· 2026Q1
Multicenter evaluation of the EasySeq full-length 16S sequencing kit for bacterial identification in clinical samples
- 0citations
- Q1SCImago
- 2026year
Short summary
A multicenter study found the EasySeq Full-Length 16S Library Prep Kit combined with the GenomeDetective pipeline (EasySeq-GD) identified 92 unique bacterial taxa missed by comparator workflows in 151 clinical samples, with 70.9% taxon-level concordance and no clinically relevant discrepancies in 92.7% of samples.
AI-generated from the title and abstract; the full text is not read.
Key points
- The EasySeq-GD workflow identified 92 unique bacterial taxa in 151 clinical samples that were missed by eight comparator workflows.
- Taxon-level results between EasySeq-GD and comparator workflows were concordant in 107/151 samples (70.9%).
- Clinically relevant discrepancies were observed in 8 samples for EasySeq-GD and 3 for comparator workflows.
- EasySeq-GD demonstrated good interlaboratory reproducibility across eight medical centers.
- 11.9% of clinical samples initially failed processing, with 5.6% remaining unresolved.
AI-generated from the title and abstract; the full text is not read.
Abstract
Bacterial culture remains essential for pathogen detection and identification, but its sensitivity is limited in cases involving fastidious microorganisms, polymicrobial infections, or samples obtained after antibiotic treatment. Targeted next-generation sequencing (tNGS) offers a culture-independent alternative and is increasingly being implemented in clinical microbiology. This multicenter study evaluated the EasySeq Full-Length 16S Library Prep Kit for Oxford Nanopore Technologies (EasySeq; NimaGen) combined with the GenomeDetective pipeline (EasySeq-GD) against eight established 16S rRNA gene- and 16–23S rRNA intergenic spacer (IS)-based workflows. Eight medical centers in the Netherlands and Belgium analyzed a mock community sample in triplicate and 20 clinical samples per center ( n = 160). Mock community analysis demonstrated consistent taxonomic profiles across centers with minimal intralaboratory variation. Of 160 clinical samples, 19 (11.9%) initially failed, of which nine (5.6%) remained unresolved. Among the remaining 151 samples, EasySeq-GD and comparator workflows shared 141 detected taxa. In addition, EasySeq-GD identified 92 unique bacterial taxa, whereas comparator workflows identified 32 unique taxa. These findings resulted in clinically relevant discrepancies in eight and three samples, respectively. Overall, EasySeq-GD demonstrated good interlaboratory reproducibility. Taxon-level results were concordant with comparator workflows in 107/151 samples (70.9%), while 140/151 samples (92.7%) showed no clinically relevant discrepancies.
The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Microbiology
Microbiology (medical)Medicine