Physics in Medicine and Biology· 2026Q2
Per-Bundle Statistical Limits and Learned-Prior Inversion in Multiplexed X-ray Imaging, with Application to Temporal CT
- 1citations
- Q2SCImago
- 2026year
Short summary
Multiplexed X-ray imaging, like Temporal CT (TCT), imposes a dose cost due to its nonlinear inversion problem, reducing Fisher information by up to 77% for certain paths compared to single-source imaging.
AI-generated from the title and abstract; the full text is not read.
Key points
- Multiplexed X-ray imaging (e.g., Temporal CT) involves a nonlinear inversion problem due to summing photon intensities before detection.
- This aggregation causes a structural loss of Fisher information, with endpoint paths retaining 43% and middle paths 23% of single-source information.
- Constant dose-inflation factors are calculated as approximately 1.53 for endpoint paths and 2.08 for middle paths.
- A learned prior network reduces the error of a constrained maximum-likelihood estimate by 27-49% for photon-starved middle paths.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Objective. Temporal computed tomography (TCT) fires N_S=3 X-ray sources simultaneously onto a shared detector, creating a pre-reconstruction inverse problem: each bundle of M=5 Poisson intensities sums unlabeled photon contributions from K=3 line integrals. Because the measurement sums exponentials rather than forming one Beer–Lambert product, log and Σ do not commute and the inversion is nonlinear. We quantify the dose cost this multiplexing imposes and how closely estimators approach that limit. Approach. We treat the 5×3 bundle as a model problem for multiplexed photon aggregation, with TCT the motivating instance. Closed-form Cramér–Rao bounds (CRBs) are expressed as dose-inflation factors against an equal-dose single-source floor, and two estimators—a converged constrained maximum-likelihood estimator and a physics-motivated residual network—are benchmarked on synthetic independent and identically distributed (i.i.d.), analytical-phantom and single-patient bundles. Main results. Aggregation imposes a structural loss: at equal attenuation only 43% of single-source Fisher information survives for the endpoint paths and 23% for the middle path, fixing constant CRB inflation ratios √(7/3)≈1.53 and √(13/3)≈2.08. The constrained maximum-likelihood estimate attains the endpoint CRBs within a few percent but stays up to 1.35× above the middle-path bound. A learned prior narrows this gap where the middle path is photon-starved: on i.i.d. data the network cuts the constrained estimate's error by 27–49% for line-integral values of 6–9, nearly matching the Bayes posterior mean's overall error; on one patient, across separate body regions, it gains comparably for values of 5–8, loses elsewhere, and never falls below the equal-dose floor. Significance. The structure (a Poisson sum of exponentials) and methodology (Fisher-information efficiencies, dose-inflation accounting) are not specific to TCT: they characterize any measurement that aggregates attenuated photons before counting, transferring with only the incidence matrix respecified. Whether a learned prior yields a generalizable dose reduction is the open question a companion paper addresses through a multi-patient corpus.
The authors' abstract, as published at the source. Physics in Medicine and Biology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Radiology, Nuclear Medicine and Imaging
Radiology, Nuclear Medicine and ImagingMedicine