PofoliaDaily literature tracker

Frontiers in Veterinary Science· 2026Q1

Effect of low-pass filtering on the reliability of center of pressure data in static posturography in dogs

Julia Wegscheider, Christiane Lutonsky, Masoud Aghapour, Nadja Affenzeller et al.

Short summary

Applying a 6 Hz low-pass Butterworth filter improves the reliability and efficiency of center of pressure (COP) data analysis in dogs, enabling shorter measurement durations (1-10 s) and fewer sequences for static posturography.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Low-pass filtering (6 Hz and 10 Hz) improves test-retest reliability of COP parameters in dogs.
  • Filtering reduces the number of sequences required to achieve a reliability threshold (ICC ≥ 0.60).
  • The 6 Hz filter demonstrated a modest advantage over the 10 Hz filter.
  • Despite filtering, measurement duration remains a significant factor influencing reliability.

AI-generated from the title and abstract; the full text is not read.

Abstract

Center of pressure (COP) analysis is widely used to assess postural stability in dogs; however, methodological variability—particularly regarding data filtering and measurement duration—limits comparability across studies. This study evaluated the effect of low-pass filtering on the reliability of COP parameters and its potential to reduce measurement duration and sampling requirements. COP data from 16 clinically sound dogs during quiet standing were analyzed using a pressure platform. A previously published dataset was expanded and re-analyzed by applying a 4th-order Butterworth low-pass filter with cutoff frequencies of 6 Hz and 10 Hz. COP parameters were calculated across multiple measurement durations (1–10 s) and sequence combinations. Reliability was assessed using intraclass correlation coefficients (ICC) for inter-observer agreement and test–retest consistency. Inter-observer reliability was excellent for all parameters regardless of filtering. Low-pass filtering improved test–retest reliability, particularly for short measurement durations, and reduced the number of sequences required to achieve the predefined reliability threshold (ICC ≥ 0.60). The 6 Hz filter showed a consistent but modest advantage over 10 Hz, especially for shorter recordings. However, significant differences between measurement durations persisted despite filtering. In conclusion, low-pass filtering enhances the reliability and efficiency of canine COP analysis, enabling shorter and thus more feasible measurement protocols without compromising data consistency. However, measurement duration remains a critical factor, emphasizing the need for standardized protocols.

The authors' abstract, as published at the source. Frontiers in Veterinary Science, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Small AnimalsVeterinary