The Iberian blackout: A black swan or a gray rhino? A protection-aware dynamic voltage security assessment
- 7citations
- Q1SCImago
- 2026year
Short summary
A new protection-aware dynamic voltage security assessment method can predict and prevent cascading voltage-related blackouts by simulating relay responses to network events.
AI-generated from the title and abstract; the full text is not read.
Key points
- Developed a protection-aware dynamic voltage security assessment method.
- The method simulates voltage at overvoltage relays to predict cascading failures.
- Successfully flagged all events causing secondary trips within relay time windows in case studies.
- Identified feasible fast reactive power actions to prevent trips when possible.
AI-generated from the title and abstract; the full text is not read.
Abstract
On 28 April 2025, the Iberian power system collapsed after a rapid voltage rise that led to widespread generation disconnections and loss of synchronism. The final report of the ENTSO-E Expert Panel attributes the blackout to several interacting factors including ineffective voltage control, fixed power factor operation, misaligned protection settings, manual shunt reactor switching, and limited observability. These factors raise a general question: given the current state, can the next trip, ramp, topology action, or shunt switching raise the voltages measured by overvoltage relays above their settings before voltage controls respond? We answer this with a protection-aware dynamic voltage security assessment. For each candidate event, the method computes the voltage at every overvoltage relay over the relay time window from a dynamic model of the network, its controls, and its relays. It predicts which relays trip after a first trip, identifies assets whose relay or measurement data are insufficient for a safety conclusion, and, when one exists, computes a minimum-cost fast reactive power action that keeps all relay voltages below their settings. Case studies on four benchmark systems and a 2000-bus system that reproduces the mechanism of the Iberian blackout show that the method flagged every event that caused a secondary trip within the relay window, never declared safe a plant that tripped within that window, and, on the benchmarks, found fast reactive power actions that prevented the trips within the relay window whenever it judged such actions feasible. These results were validated with nonlinear time-domain simulations. The implementation code and a visual guide of this work are publicly available.
The authors' abstract, as published at the source. Applied Energy, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Electrical and Electronic Engineering