PofoliaDaily literature tracker

The Journal of Chemical Physics· 2026Q1

Modeling the inner electric double layer using short-range machine learning potentials: A critical assessment

Lucas B. T. de Kam, Jiaxin Zhu, Ankit Mathanker, Katharina Doblhoff-Dier et al.

Short summary

Short-range machine learning potentials (MLIPs) can reliably model the inner electric double layer of charged Au/electrolyte interfaces when trained on a single charge state, but yield inconsistent predictions when trained on multiple charge states due to MLIPs being "blind" to surface charge.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Short-range MLIPs can accurately model the inner electric double layer of Au/electrolyte interfaces when trained on a single surface charge.
  • MLIPs trained on datasets with multiple charge states fail to consistently predict interfacial water orientation and ion distributions.
  • The failure is attributed to MLIPs being "blind" to the specific surface charge.
  • Message-passing MLIPs demonstrate slightly better robustness to mixed-charge training data but are still prone to errors.

AI-generated from the title and abstract; the full text is not read.

Abstract

Atomistic simulations of electrochemical interfaces typically require large system sizes and long simulation times to obtain reliable thermodynamic properties. In this context, machine learning interatomic potentials (MLIPs) allow for computationally efficient sampling compared to density functional theory-based molecular dynamics simulations. Although conventional short-range MLIPs are recognized as inadequate for modeling the (potentially nanometer-wide) diffuse layer, they may still be capable of describing the inner electric double layer that is relevant for electrochemical reactions. Here, we evaluate the performance of common (short-ranged) MLIP architectures [the deep potential DP, the (graph) atomic cluster expansion-based models GRACE and MACE, and the pre-trained eSEN-OC25] for charged Au/electrolyte interfaces. In the evaluation, we focus on the effect of message passing and on the potentially adverse effect of data interference when training for a broad range of surface charges. Our results suggest that both local and message-passing models are able to reliably learn the interfacial structure when training on a single charge state. However, when trained on datasets that span multiple charge states, the MLIPs tested yield inconsistent predictions of interfacial water orientation and ion distributions. This behavior can be traced to the MLIPs being "blind" to the actual surface charge. Message-passing models show somewhat greater robustness to mixed-charge training data, likely due to their larger receptive field, but are still prone to artifacts and errors in the description of the interfacial structure. Overall, our results provide practical guidance on the expected accuracy and cross-charge-state transferability of short-ranged MLIPs for the description of the inner layer of electrode/electrolyte interfaces that will be relevant to their use in computational electrocatalysis.

The authors' abstract, as published at the source. The Journal of Chemical Physics, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Materials Chemistry

Materials ChemistryMaterials Science