Biomechanics and Modeling in Mechanobiology· 2026Q2
In Vivo cardiac biomechanical model parameter estimation from ultrafast shear wave elastography
- 1citations
- Q2SCImago
- 2026year
Short summary
A computational framework decomposes myocardial stiffness measurements from ultrafast shear wave elastography (SWE) into passive structural properties and active contractility using a closed-loop electromechanical model.
AI-generated from the title and abstract; the full text is not read.
Key points
- A novel computational framework separates passive myocardial stiffness from active contractility using ultrafast shear wave elastography (SWE).
- The personalization process involves identifying a passive hyperelastic baseline and then estimating active contractile parameters.
- The method was validated on 20 healthy pediatric volunteers, achieving high fidelity in reproducing subject-specific stiffness trajectories.
- Uncertainty analysis confirmed the practical identifiability and stability of the estimated active parameters.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Quantifying myocardial stiffness (MS) over the full cardiac cycle offers a direct window into tissue structure and mechanics, yet translating time-resolved shear wave elastography (SWE) into intrinsic material properties remains a complex inverse problem. While SWE provides detailed stiffness quantification, these measurements combine passive structural properties with active contractility under subject-specific loading conditions. In this work, we present a computational framework to decompose these contributions using a closed-loop reduced-order electromechanical model. We formulate the personalization process as a sequential inverse problem: first, a passive hyperelastic baseline is identified from the late-diastolic window; second, active contractile parameters are estimated by fitting the full-cycle waveform using a regularized covariance matrix adaptation evolution strategy (CMA-ES). We validated this framework on a cohort of healthy pediatric volunteers (n=20). The personalized models reproduced subject-specific stiffness trajectories with high fidelity (median cross-correlation 0.997, nRMSE 1.02). Uncertainty analysis confirmed the practical identifiability of the active parameters, with stable convergence across random initializations. This study establishes a computationally efficient, robust pipeline for converting non-invasive SWE assessments into interpretable mechanical signatures, paving the way for physics-informed phenotyping in clinical cohorts.
The authors' abstract, as published at the source. Biomechanics and Modeling in Mechanobiology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Radiology, Nuclear Medicine and Imaging
Radiology, Nuclear Medicine and ImagingMedicine