Buildings· 2026Q1
Performance-Normalized Cradle-to-Gate Carbon Screening of Polymer-Modified Cementitious Repair Mortars Using Standardized Functional Units
- 1citations
- Q1SCImago
- 2026year
Short summary
A new framework normalizes the cradle-to-gate carbon footprint of polymer-modified repair mortars by their performance, revealing that while some modifications significantly enhance durability, their carbon cost must be carefully evaluated against specific functional benefits.
AI-generated from the title and abstract; the full text is not read.
Key points
- A novel framework normalizes carbon emissions of repair mortars by performance metrics and standardized functional units (e.g., 1 m3, 1 kg dry mix, 1 m2 repair layer).
- Epoxy-modified mortars reduced mass loss by up to 96.0% but increased CO2e emissions from 264 to 422–857 kg CO2e/m3.
- A styrene–butadiene rubber mortar demonstrated a 26% lower chloride-normalized GWP when paired with a regional EPD.
- The study propagated uncertainties in emission factors and test results using Monte Carlo simulations.
AI-generated from the title and abstract; the full text is not read.
Abstract
Polymer-modified cementitious repair mortars improve adhesion and durability but usually increase cradle-to-gate (A1–A3) emissions. This study develops a performance-normalized embodied-carbon screening framework that compares repair materials on standardized functional units (1 m3, 1 kg dry mix, 1 m2 repair layer) and on declared repair functions. A database of 55 studies, 141 mixture records, and 243 endpoints was compiled, and 19 studies met predefined criteria for quantitative extraction. Two within-study case studies were analyzed, and emission factor and test-result uncertainties were propagated by Monte Carlo simulation. In epoxy-modified mortars (reconstructed inventory) exposed to sulfuric acid, modification reduced mass loss by 57.9–96.0% but increased emissions from 264 to 422–857 kg CO2e/m3; the 5% resin mixture had the lowest incremental carbon cost and the 20% mixture the lowest deterioration-rate-normalized GWP in >99% of simulations. In styrene–butadiene rubber mortars, the cationic latex reduced the chloride migration coefficient by 31.5% and, with a regional EPD, lowered the chloride-normalized GWP by 26%; this advantage is lost above a latex emission factor of 2.66 kg CO2e/kg. In a geopolymer benchmark, a declared desirability index ranked one of the same two mixtures first in all predefined scenarios. The framework supports screening rather than definitive ranking.
The authors' abstract, as published at the source. Buildings, 2026 · DOI ↗