PofoliaDaily literature tracker

Sustainability· 2026Q1

Toward Cleaner Production of Titanium Dioxide via the Sulfate Route: A Full-Scale Retrofit Based on Continuous Acid Digestion, Continuous Cooling Crystallization and Mechanical Vapor Recompression

Daibing Luo, Daichuan Ma, Liangzhuan Wu, Gongming Deng

Short summary

A full-scale retrofit of a TiO2 plant using continuous acid digestion, continuous cooling crystallization, and mechanical vapor recompression reduced specific energy consumption by 20.5% and production costs by 10.4%, while also lowering CO2 emissions by 30.7%.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Continuous acid digestion increased Ti digestion yield from 96.0% to 98.0%.
  • Waste acid regeneration and reuse reduced 98% H2SO4 consumption by 23% per tonne of TiO2.
  • Continuous cooling crystallization eliminated process steam demand and halved crystallization cycle time.
  • Mechanical vapor recompression cut steam demand by 83.3% and avoided 27,420 t/a of CO2.
  • Overall specific energy consumption fell by 20.5% (to 914.41 kgce/t) and production costs by 10.4% (to 10,351 CNY/t).

AI-generated from the title and abstract; the full text is not read.

Abstract

The sulfate route still dominates titanium dioxide (TiO2) production in China, but is burdened by burst emissions of sulfur oxides (SOx), dilute waste acid, ferrous sulfate, titanium gypsum and high steam demand. This work reports a full-scale retrofit of a 50 kt/a sulfate-route TiO2 plant in China that processes a domestic ilmenite concentrate, in which three unit operations were replaced and integrated into one continuous system: continuous acid digestion (CAD), continuous cooling crystallization (CCC) and mechanical vapor recompression (MVR). Over routine operation, continuous digestion raised the Ti digestion yield from 96.0% to 98.0%. The acid-to-ore ratio was essentially unchanged, yet the 98% H2SO4 consumption fell from 3.52 to 2.73 t per tonne of TiO2, because about 70% of the waste acid was regenerated to 55 wt% and returned to the pre-mix tank. Digestion off-gas fell from 16,575 to 4284 Nm3 per tonne of TiO2. CCC eliminated process steam (1.39 to 0 t/t) and halved the crystallization cycle. MVR concentration cut the steam demand of the concentration step by 83.3% and avoided 27,420 t/a of CO2. Specific energy consumption on the full plant boundary used by GB 32051-2024, that is the measured units plus a fixed allowance for post-treatment equipment not yet installed, fell from 1150.17 to 914.41 kg of coal equivalent per tonne (kgce/t) (−20.5%), which corresponds to Grade 2 (≤1000 kgce/t) of GB 32051-2024 for sulfate-route titanium dioxide pigment; over the units actually operated in both periods the fall was from 887.33 to 651.57 kgce/t (−26.6%). The production cost fell from 11,552 to 10,351 CNY/t (−10.4%) with no change in the quality attributes compared across the two periods. With 25% of the electricity supplied by an on-site photovoltaic array, specific CO2 emissions fell from 2.384 to 1.653 t/t (−30.7%). Particulate matter, sulfuric acid mist, SO2 and NOx measured at the stack were within the limits of GB 16297-1996 and GB 9078-1996, and volatile organic compounds (VOCs) monitored in the production zone were below the 2.0 mg/m3 limit applied there. Combining these three intensification measures in one continuous process thus delivers simultaneous energy, emission and economic benefits and offers a replicable template for the sector.

The authors' abstract, as published at the source. Sustainability, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Metals and Alloys

Metals and AlloysMaterials Science