PofoliaDaily literature tracker

Journal of the American Veterinary Medical Association· 2026Q1

Commercially available objective gait evaluation systems show good to excellent reliability in horses across hard-surface types and multiple operators

Jenna L. McPeek, Adrianne Caudill, Emma Adam, Sophia Carattini et al.

Short summary

Objective gait evaluation systems (AI-based smartphone app Sleip, and IMU systems Equinosis Q Lameness Locator and Equisym) demonstrated moderate to excellent intrasystem reliability (ICC > 0.50) and interoperator reliability (ICC > 0.72) in horses across different hard surfaces.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Objective gait evaluation systems (Sleip, Equinosis Q Lameness Locator, Equisym) were assessed for reliability in horses.
  • Intrasystem reliability was moderate to excellent (ICC > 0.50) across different hard surfaces.
  • Interoperator reliability for the IMU systems was also moderate to excellent (ICC > 0.72).
  • Measurement error remained stable across various testing conditions.

AI-generated from the title and abstract; the full text is not read.

Abstract

Objective: To evaluate the intrasystem reliability of an AI-based smartphone application Sleip (AI-SPA), the inertial measurement unit (IMU) system Equinosis Q Lameness Locator (LL), and the IMU system Equisym (ES) across 2 different hard surfaces and to assess the interoperator reliability for the 2 IMU systems. Methods: 8 mixed-breed research horses, aged 4 to 12 years, with varying degrees of gait asymmetries were utilized. To assess intrasystem reliability, horses were in-hand, straight-line trotted on either epoxy-coated concrete or rubber-coated concrete. Three trials were performed for LL and ES, while 6 concurrent trials were performed for AI-SPA. Interoperator reliability was assessed with 4 operators on the rubber-coated concrete only. Intraclass correlation coefficients and SE of measurements were calculated for 4 outcome parameters common to all systems as well as a variety of system-specific outcome parameters for LL and ES. Results: Nearly all intraclass correlation coefficients indicated moderate to excellent intrasystem reliability (> 0.50) across the 3 systems (AI-SPA, 0.40 to 0.85; LL, 0.73 to 0.94; ES, 0.44 to 0.99) and were comparable between surfaces. Interoperator reliability was moderate to excellent for both LL (0.72 to 0.92) and ES (0.73 to 0.96). Standard error of measurement values remained relatively stable across study conditions. Conclusions: Despite inherent horse variability and minor differences in testing conditions, objective gait evaluation systems consistently produced measurements indicating moderate to excellent reliability and low measurement error. Clinical Relevance: These findings indicate that observed changes in system output are unlikely to be impacted by operator or hard-surface effects, supporting clinical reliability of these systems in routine practice when utilizing manufacturers' instructions.

The authors' abstract, as published at the source. Journal of the American Veterinary Medical Association, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

EquineVeterinary