PofoliaDaily literature tracker

Scientific Reports· 2026Q1

BIS-based model reference adaptive control of anesthesia depth under patient variability and time-varying delays

Raha Rahimi, Marzieh Kamali, Fazaneh Shayegh, Zahra Baharlouei

Short summary

A novel Model Reference Adaptive Control (MRAC) strategy for closed-loop anesthesia management using propofol and remifentanil achieves stable tracking across heterogeneous virtual patients and time-varying delays, maintaining the Bispectral Index (BIS) between 40-60 with minimal overshoot (<5%) during induction.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Proposes an adaptive closed-loop anesthesia control system using propofol and remifentanil.
  • The MRAC strategy compensates for patient variability and time-varying delays without patient-specific tuning.
  • Simulations show induction settling times of 4-6 minutes with <5% overshoot.
  • Maintains Bispectral Index (BIS) within the clinically acceptable range of 40-60.
  • Achieves competitive tracking performance across heterogeneous virtual patients.

AI-generated from the title and abstract; the full text is not read.

Abstract

General anesthesia plays a critical role in modern surgical care, requiring accurate regulation of hypnotic and analgesic drug administration to maintain unconsciousness and analgesia. A major challenge in anesthesia control is the presence of significant inter-patient variability and physiological time-varying delays. Conventional control approaches often rely on manual tuning or patient-specific parameter identification, limiting their applicability in real clinical settings. This study proposes a Model Reference Adaptive Control (MRAC) strategy for automated closed-loop regulation of anesthesia depth using propofol and remifentanil. The proposed framework incorporates a Pharmacokinetic/Pharmacodynamic model and compensates for nonlinear drug-response behavior through an inverse Hill-function approach. A key advantage of the proposed adaptive controller is its independence from patient-specific tuning and prior parameter identification, enabling real-time personalized anesthesia management without model recalibration. Simulation results on a heterogeneous virtual patient population demonstrate settling times of approximately 4–6 min during induction with minimal overshoot (< 5%). The Bispectral Index (BIS) was successfully maintained within the clinically acceptable range of 40–60, with an average value close to 50 and small deviations (± 2). Compared with previously reported anesthesia control strategies, the proposed MRAC approach achieves competitive tracking performance while maintaining stable tracking across heterogeneous virtual simulated patients and time-varying delays. These findings suggest that the proposed strategy provides a promising solution for robust and individualized closed-loop anesthesia management.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Anesthesiology and Pain Medicine