Experimental shear behaviour of self-compacting concrete dry joints in PCSBs under combined axial, bending and shear forces

Celia Traver-Abella, José Luis Bonet, Pedro F. Miguel, Miguel Ángel Fernández Prada

Short summary

Self-compacting concrete dry joints in precast concrete segmental bridges (PCSBs) exhibited up to 49% higher shear capacity under uniform confining stress compared to eccentric loading, based on 22 push-off tests.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Dry joints in PCSBs are critical for transmitting combined forces between segments.
  • Uniform confining stress resulted in up to 49% higher shear capacity compared to eccentric loading in dry joints.
  • The study tested 22 specimens with three-keyed dry joints using various concrete types and fiber contents.
  • Existing AASHTO and Fouré et al. formulations for shear strength prediction were evaluated under combined loading.

AI-generated from the title and abstract; the full text is not read.

Abstract

The behaviour of precast concrete segmental bridges (PCSBs) fundamentally depends on the joints, which represent discontinuity zones and must be capable of transmitting combined forces (axial, bending and shear) between segments. Under service conditions, joints in PCSBs are expected to remain in full contact, although partial opening may occur under ultimate load conditions. Castellated dry joints with external prestressing are increasingly used due to their efficient construction, environmental advantages and adequate mechanical interlock. Although numerous experimental and numerical studies have investigated their shear behaviour and capacity, studies under combined forces are very limited. The test configuration developed by the authors allows the shear behaviour of the joints to be investigated independently of the global behaviour of the segmental beams. This paper presents 22 push-off tests, 17 from the present experimental programme and 5 from previous studies conducted by the authors, on specimens with three-keyed dry joints made of different concrete types and fibre contents, subjected to varying axial forces and eccentricities. The influence of these variable parameters on cracking patterns and shear capacity was studied. In addition, the results obtained under eccentric loading were compared with those from specimens subjected to uniform confining stress, which showed shear capacities up to 49% higher than those under eccentric loading. Finally, the accuracy of the AASHTO and Fouré et al. formulations for predicting shear strength under combined loading was evaluated for different concrete types, with and without steel fibres.

The authors' abstract, as published at the source. Structures, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Building and Construction

Building and ConstructionEngineering