PofoliaDaily literature tracker

Drug Testing and Analysis· 2026Q2

Quantitative Analysis of Lysergic Acid Diethylamide: A Ring Study Among Five Swiss Drug Checking Services

Manuela Carla Monti, Emilia Gianola, Raoul Pieter Joost Koning, Mireia Ventura et al.

Short summary

A ring study involving five Swiss drug checking services found low interlaboratory variability (8%-16.5% relative standard deviation) and mean accuracy from -5.3% to -13.0% for LSD quantification in blotters and solutions, confirming the reliability of current analytical methods.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Five Swiss drug checking services participated in an interlaboratory ring trial for LSD quantification.
  • Analytical techniques included HPLC-DAD, GC-MS, and HPLC-MS/MS.
  • Interlaboratory variability was low, with relative standard deviations between 8% and 16.5%.
  • Mean accuracy ranged from -5.3% to -13.0% for LSD quantification.
  • Mass spectrometry-based methods showed larger deviations, and liquid samples had higher variability.

AI-generated from the title and abstract; the full text is not read.

Abstract

Lysergic acid diethylamide (LSD) is a serotonergic psychedelic with active dosages in the microgram range. Accurate information about the LSD content of blotters is essential for harm reduction. However, drug checking services (DCS) across Europe have reported that service users expect LSD contents to be considerably higher than what is measured analytically, raising questions about the accuracy and reliability of current methods used in DCS settings. This study presents an interlaboratory ring trial on LSD quantification within the context of drug checking. Five Swiss DCS laboratories participated, each employing different analytical techniques (HPLC-DAD, GC-MS, and HPLC-MS/MS) and extraction procedures. Three sample types were distributed: two LSD-infused blotters and one methanolic LSD solution. The quantitative results were corrected based on purity determined by proton nuclear magnetic resonance spectroscopy (qNMR) of the reference standard. Interlaboratory variability was low, with relative standard deviations of 8%-16.5% and mean accuracy ranging from -5.3% to -13.0%. Variability was higher for the liquid sample. The largest deviations were reported for mass spectrometry-based methods. The study confirmed the reliability of LSD quantification across participating DCS laboratories. Additional factors that could potentially contribute to the reported discrepancy were discussed: limited stability of LSD, potential inconsistencies in clandestine blotter production methods, and user expectations shaped by marketing or anecdotal reports. The findings support the accuracy of current LSD quantification methods in drug checking settings and provide a foundation for future proficiency testing. Reliable chemical data is essential for accurate dosing and effective harm reduction.

The authors' abstract, as published at the source. Drug Testing and Analysis, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

ToxicologyPharmacology, Toxicology and Pharmaceutics